beautypg.com

General repair information – AIRLESSCO SP200 User Manual

Page 11

background image

General Repair Information

3A0997F

11

General Repair Information

Keep all screws, nuts, washers, gaskets, and electri-
cal fittings removed during repair procedures. These
parts usually are not provided with replacement kits.

Test repairs after problems are corrected.

If sprayer does not operate properly, review repair
procedure to verify you did it correctly. See Basic
Troubleshooting
, page 12 and Advanced Trouble-
shooting
, page 17.

Overspray may build up in the air passages.
Remove any overspray and residue from air pas-
sages and openings in the enclosures whenever
you service sprayer.

Do not operate the sprayer without the cover in
place. Replace if damaged. Covers direct cooling air
around motor to prevent overheating.

Flammable materials spilled on hot, bare, motor
could cause fire or explosion. To reduce risk of burns,
fire or explosion, do not operate sprayer with cover
removed.

To reduce risk of serious injury, including electric
shock:

• Do not touch moving or electric pars with fingers

or tools while testing repair.

• Unplug sprayer when power is not required for

testing.

• Install all covers, gaskets, screws and washers

before you operate sprayer.

NOTICE

• Do not run sprayer dry for more than 30 seconds.

Doing so could damage pump packings.

• Protect the internal drive parts of this sprayer

from water. Openings in the cover allow for air
cooling of the mechanical parts and electronics
inside. If water gets in these openings, the
sprayer could malfunction or be permanently
damaged.

• Prevent pump corrosion and damage from freez-

ing. Never leave water or water-base paint in
sprayer when its not in use in cold weather.
Freezing fluids can seriously damage sprayer.
Store sprayer with Pump Armor to protect
sprayer during storage.