beautypg.com

Trouble shooting, Maintenance, Accessories – Emerson CF704PB02 User Manual

Page 7: Warning

background image

WARNING:

FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER

BEFORE TROUBLE SHOOTING YOUR FAN.

Trouble Shooting

TROUBLE

PROBABLE CAUSE

SUGGESTED REMEDY

1. Fan will not

1. Reversing switch in neutral position.

1. Make sure reversing switch position is all the

start.

way to one side.

2. Fuse or circuit breaker blown.

2. Check main and branch circuit fuses or circuit

breakers.

3. Loose power line connections to the fan, or

3. Check line wire connections to fan and switch

loose switch wire connections in switch

wire connections in the switch housing.housing.

2. Fan sounds

1. Blades not attached to fan.

1. Attach blades to fan before operating.

noisy.

2. Loose screws in motor housing.

2. Check to make sure all screws in motor

housing are snug (not over-tight).

3. Screws securing fan blade flanges to motor

3. Check to make sure the screws which attach

are loose.

the fan blade flanges to the motor hub are tight.

4. Switch housing binding against blade hub.

4. Check to make sure that the switch housing

does not bind against the blade hub.

5. Wire connectors inside switch housing rattling.

5. Check to make sure wire connectors in switch

housing are not rattling against each other or

against the interior wall of the switch housing.

6. Screws holding flanges to blades are loose.

6. Tighten screws securely.

3. Fan wobbles

1. Setscrew in motor coupling is loose.

1. Tighten the setscrew and then tighten the

or shakes

jam nut.

excessively.

2. Setscrew in hanger ball/downrod assembly is

2. Tighten the setscrew in the hanger ball/downrod

loose.

assembly.

3. Screws securing fan blade flanges to motor

3. Check to be sure screws which attach the fan

are loose.

blade flanges to the motor hub are tight.

4. Fan blade flanges not seated properly.

4. Check to be sure the fan blade flanges seat

firmly and uniformly to the surface of the
motor hub. If flanges are seated incorrectly,
loosen the flange screws and retighten
according to the procedure in the section on
"How to Put Your Ceiling Fan Together".

5. Hanger bracket and/or ceiling outlet box is not

5. Tighten the hanger bracket screws to the

securely fastened.

outlet box, and/or secure outlet box.

6. Fan blades out of balance.

6. Interchanging an adjacent (side-by-side)blade

pair can redistribute the weight and result in
smoother operation.

7

Maintenance

IMPORTANT CARE INSTRUCTIONS

For Your Ceiling Fan

Periodic cleaning of your new ceiling fan is the only
maintenance that is needed.

When cleaning, use only a soft brush or lint free cloth
to avoid scratching the finish.

Abrasive cleaning agents are not required and should
be avoided to prevent damage to finish.

1. Ceiling Fan Light Kits (see store or catalog).

2. Ceiling Fan/Light Controls (see store or catalog).

Accessories

1. Ceiling Fan Light Kits (see store or catalog).

2. Ceiling Fan/Light Controls (see store or catalog).

3. Downrod Extension Kits (see store or catalog).

Do not use water when cleaning your ceiling fan. It
could damage the motor or the blades and create the
possibility of an electrical shock.

WARNING

!

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson. Substitution of parts or accessories not
designated for use with this product by Emerson
could result in personal injury or property damage.

The use of any other control not specifically
approved for this fan could result in fire, shock and
personal injury.

WARNING

!

WARNING

!

To reduce the risk of fire or electrical shock, do not
use this fan with any solid-state speed control
device.

WARNING

!

!

This manual is related to the following products: