6641-2222

Type tests and environmental conditions

Electromagnetic Compatibility
Phenomena

Standard

Description

Test Levels

ESD

EN 61000-4-2

Enclosure contact
discharge immunity

±6 kV

Enclosure air discharge
immunity

±8 kV

RF field AM modulated

EN 61000-4-3

Enclosure RF immunity

20 V/m
80 – 2700 MHz

Fast transients

EN 61000-4-4

Signal port immunity

±2 kV

Power port immunity

±2 kV

Surges

EN 61000-4-5

Power port immunity

±2 kV (L-E)
±1 kV (L-L)

EN 50155:2001

Power port immunity

±8.4 kV (L-E)
±8.4 kV (L-L)

Conducted RF emision

EN 61000-4-6

Signal port immunity

10 V/m
0.15 – 80 MHz

Power port immunity

10 V/m
0.15 – 80 MHz

Power frequency magnetic field EN 61000-4-8

Enclosure immunity

300 A/m
0, 16.7, 50 Hz

Pulsed magnetic field

EN 61000-4-9

Enclosure immunity

300 A/m

Voltage interruption

EN 50155

Residual voltage 0%

10 ms

Supply overvoltage and
undervoltage

EN 50155

Overvoltage 140%
Residual voltage 60%

100 ms & 1000 ms
100 ms

Radiated emission

EN 55011
Limits: EN 50121-3-2

Enclosure measurement

40 dBµV/m QP
30 – 230 MHz
47 dBµV/m QP
230 – 1000 MHz

Conducted emission

EN 55011
Limits: EN 50121-3-2

Power port measurement 99 dBµV QP

0.15 – 5 MHz
93 dBµV QP
5 – 30 MHz

Signal port measurement

99 dBµV QP
0.15 – 5 MHz
93 dBµV QP
5 – 30 MHz

Environmental
Temperature

Operating

–40 to +70°C* (–40 to +158°F)

Storage & Transport

–40 to +70°C (–40 to +158°F)

Humidity

Operating

5 to 95% relative humidity

Storage & Transport

5 to 95% relative humidity

Altitude

Operating

2 000 m / 70 kPa

Reliability prediction (MTBF)

MIL-HDBK- 217F

Operating

306 115 h

IEC 60068-2-64

Operating

Vertical 2.0 m/s² Transverse
2.0 m/s² Longit. 2.0 m/s²

Non operating

11.4 m/s²

Shock

IEC 60068-2-27

Operating

10 g, 30 ms Half sine ±3 shocks

IEEE 1478

Operating

20 g, 11 ms Saw tooth ±3 shocks

Packaging
Dimension W x H x D

175 x 100 x 144 mm

Weight

2295 g

Degree of protection

IEC 529

Enclosure

IP65**

Cooling

Convection

Mounting

Rear panel wall mounting

* Refer to “Safety” section
** Provided all connectors are connected with IP65 cabling or fitted with protective caps (delivered with the unit),