Type tests and environmental conditions – Westermo RFR-12-FB User Manual
Page 7
7
6641-2222
Type tests and environmental conditions
Electromagnetic Compatibility
Phenomena
Standard
Description
Test Levels
ESD
EN 61000-4-2
Enclosure contact
discharge immunity
±6 kV
Enclosure air discharge
immunity
±8 kV
RF field AM modulated
EN 61000-4-3
Enclosure RF immunity
20 V/m
80 – 2700 MHz
Fast transients
EN 61000-4-4
Signal port immunity
±2 kV
Power port immunity
±2 kV
Surges
EN 61000-4-5
Power port immunity
±2 kV (L-E)
±1 kV (L-L)
EN 50155:2001
Power port immunity
±8.4 kV (L-E)
±8.4 kV (L-L)
Conducted RF emision
EN 61000-4-6
Signal port immunity
10 V/m
0.15 – 80 MHz
Power port immunity
10 V/m
0.15 – 80 MHz
Power frequency magnetic field EN 61000-4-8
Enclosure immunity
300 A/m
0, 16.7, 50 Hz
Pulsed magnetic field
EN 61000-4-9
Enclosure immunity
300 A/m
Voltage interruption
EN 50155
Residual voltage 0%
10 ms
Supply overvoltage and
undervoltage
EN 50155
Overvoltage 140%
Residual voltage 60%
100 ms & 1000 ms
100 ms
Radiated emission
EN 55011
Limits: EN 50121-3-2
Enclosure measurement
40 dBµV/m QP
30 – 230 MHz
47 dBµV/m QP
230 – 1000 MHz
Conducted emission
EN 55011
Limits: EN 50121-3-2
Power port measurement 99 dBµV QP
0.15 – 5 MHz
93 dBµV QP
5 – 30 MHz
Signal port measurement
99 dBµV QP
0.15 – 5 MHz
93 dBµV QP
5 – 30 MHz
Environmental
Temperature
Operating
–40 to +70°C* (–40 to +158°F)
Storage & Transport
–40 to +70°C (–40 to +158°F)
Humidity
Operating
5 to 95% relative humidity
Storage & Transport
5 to 95% relative humidity
Altitude
Operating
2 000 m / 70 kPa
Reliability prediction (MTBF)
MIL-HDBK- 217F
Operating
306 115 h
IEC 60068-2-64
Operating
Vertical 2.0 m/s² Transverse
2.0 m/s² Longit. 2.0 m/s²
Non operating
11.4 m/s²
Shock
IEC 60068-2-27
Operating
10 g, 30 ms Half sine ±3 shocks
IEEE 1478
Operating
20 g, 11 ms Saw tooth ±3 shocks
Packaging
Dimension W x H x D
175 x 100 x 144 mm
Weight
2295 g
Degree of protection
IEC 529
Enclosure
IP65**
Cooling
Convection
Mounting
Rear panel wall mounting
* Refer to “Safety” section
** Provided all connectors are connected with IP65 cabling or fitted with protective caps (delivered with the unit),
tightened to the specified torque