Dip-switch settings, Before setting dip-switches, S2 dip-switch – Westermo ODW-641 User Manual
Page 16

16
6650-2291
DIP-switch settings
Before setting DIP-switches:
Prevent damage to internal electronics from electrostatic discharges (ESD)
by discharging your body to a grounding point (e.g. use of wrist strap).
!
S2
S1
S2 DIP-switch
ON
1 2 3 4 5 6 7 8
Multidrop or redundant
ring slave unit.
N/A for ODW-641
ON
1 2 3 4 5 6 7 8
Multidrop end unit. E.g. the first or
last unit in a multidrop network.
Always
"ON" for ODW-641
ON
1 2 3 4 5 6 7 8
Redundant ring master unit.
Only one master unit allowed
in a ring. N/A for ODW-641
ON
1 2 3 4 5 6 7 8
65535 tbit interruption in receiving
frames, until inactive BA
.
ON
1 2 3 4 5 6 7 8
10 seconds interruption in receiving
frames, until inactive BA
*.
ON
1 2 3 4 5 6 7 8
20 seconds interruption in receiving
frames, until inactive BA
*.
ON
1 2 3 4 5 6 7 8
5 seconds interruption in receiving
frames, until inactive BA
*.
* See section “About the automatic data rate detection”
on page 11 for a more detailed description.