6651-22651
Multidrop application
Follow the steps below to get the unit up and running in a simple application.
Prepare the units
Configure the network, with master and slaves. Check that it is running correctly with
…
the electrical serial network.
Prepare the fibre optical network
Multidrop, mid units (CH 1 & CH 2). Set switch S2:1 and 2 to ON.
…
Multidrop, end units (CH 1 only). All switches should be set to OFF if it is
…
protocol independent and Switch S2: 1 to ON if it is protocol dependent.
Connect the fibre links between the units.
…
Connect the power supply to all units.
…
• The Fibre links should be in operation, indicated by active CH 1 and CH 2 LED’s.
Connect each of the slaves to the serial port of the corresponding ODW-630-F2.
…
Connect the master to the port of one ODW-630-F2
…
The Multidrop application is up and running.
…
Note! ODW-620-F1 or ODW-630-F1 can be used as end units.
TX
RX
TX
RX
TX
RX
TX
RX
TX
RX
TX
RX
TX
RX
TX
RX
CH 2
CH 1
CH 2
CH 1
CH 2
CH 1
CH 2
CH 1
PLC
Slave
PLC
Master
PLC
Slave
PLC
Slave
- TR-36B (88 pages)
- TD-36 (44 pages)
- TR-36 (36 pages)
- TR-36B (20 pages)
- IDW-90 AT (97 pages)
- GD-01 (20 pages)
- GD-01 (206 pages)
- MRI-128-F4G (175 pages)
- MRI-128-F4G (169 pages)
- GDW-11 (40 pages)
- GDW-11 485 (380 pages)
- Lynx Series (28 pages)
- ODW-720-F2 (36 pages)
- ODW-720-F1 (20 pages)
- ODW-720-F1 (24 pages)
- ODW-730-F1 (24 pages)
- ODW-730-F2 (36 pages)
- DDW-120 (24 pages)
- DDW-226-EX (24 pages)
- DDW-226-EX (24 pages)
- DR-270 (28 pages)
- DR Series (460 pages)
- ED-2x0 (20 pages)
- MRD-3x0 (199 pages)
- FD-80 (24 pages)
- FDV-206-1D-1S (24 pages)
- GD-01 US (24 pages)
- LD-01 (8 pages)
- IDW-90 (44 pages)
- Lynx-x10-F2G (16 pages)
- Lynx-x08-F2G-S2 (20 pages)
- MDI-110-F3x (16 pages)
- MR-2x0 (28 pages)
- ODW-642 (28 pages)
- PII PoE Injector (12 pages)
- Viper Series (977 pages)
- SDI-5xx (12 pages)
- RFI-xx (32 pages)
- SDI-8xx (16 pages)
- RFIR-xxx (24 pages)
- TD-29 (16 pages)
- SDW-5xx (24 pages)
- TD-23 (24 pages)
- TD-29P (16 pages)
- Viper 408 (20 pages)