Configuration, S1 dip-switch, Factory settings – Westermo ODW-620-F1 User Manual
Page 15: S2 dip-switch
15
6651-22621
Configuration
All needed configurations and parameter settings are done by the DIP-switches, located
under the top lid.
!
DIP-switch settings
Before DIP-switch settings:
Prevent damage to internal electronics from electrostatic discharges (ESD) by
discharging your body to a grounding point (e.g. use of wrist strap)
Note: Disconnect power before DIP-switch settings.
S2
S1
S1 DIP-switch
ON
1 2 3 4 5 6 7 8
CTS always active
ON
1 2 3 4 5 6 7 8
RTS signal will be transferred to
remote modem. When the remote
modem receives RTS. CTS will be
set to high.
Factory settings
ON
1 2 3 4 5 6 7 8
S1
ON
1 2 3 4 5 6 7 8
S2
S2 DIP-switch
ON
1 2 3 4 5 6 7 8
Set status port of local fibre link
error*
* SW 2:6 ON: The status relay only change status in the unit that is connected to the receive side.