Getting started – Westermo MR-200 User Manual
Page 15
15
6615-2202
Getting started
IP Address
The default IP address of the MR-2xx when delivered is 192.168.0.99.
IP address configuration
The IP address is configurable by the Web tool and/or by using a terminal program.
Below is an description of how to configure the IP address by using a terminal program.
1. If the address is known, connect to the unit from a Web browser with the address of
the MR-2xx. If the address is unknown, connect the serial RS-232 interface to a
terminal program with settings:
Data rate: 115.2 bit/s
Data bits: 8
Stop bits: 1
Parity: None
Flow control: None
2. Use any terminal-program to setup the IP-address, gateway and subnetmask.
Eth 0 ipaddr xxx.xxx.xxx.xxx (set up IP-address)
Eth 0 gateway yyy.yyy.yyy.yyy (set up Gateway)
Eth 0 mask zzz.zzz.zzz.zzz (set up subnetmask)
Eth 0 status (check settings)
Config 0 save (save configuration)
3. The unit is now ready for a complete configuration by the Web tool. Address MR-2xx
in a browser with the configured IP address. Note that the used computer have to be
on the same network as MR-2xx.
Username and Password for configuration
The MR-2xx is username and password protected. These are used when connecting with
Web browser during configuration and with Telnet for diagnostics.
Default username: username
Default password: password
Restore Factory default settings
Note! This will clear your customized settings.
The factory default settings can be restored using the reset switch on the bottom of the
unit. Pressing (~15 sec) the switch gently with the tip of a pen or other suitable imple-
ment will generate a hardware reset.
Note! If the default address of the unit is valid on the connected network it is possible
to access the unit directly from a browser.
It is important to allow the MR-2xx to complete the restore procedure. DO NOT press
the reset button again or power cycle the unit for at least 2 minutes.