Westermo Lynx-x05-S1 User Manual
Page 7
7
6643-2230
Environmental
Temperatures
Operating
–40 to +70°C (–40 to +158°F)*
Storage and transport
–50 to +85°C (–58 to +185°F)
Humidity
Operating
5 to 95 % relative humidity
Storage and transport
5 to 95 % relative humidity
Altitude
Operating
2 000 m / 70 kPa
MTBF
MIL-C217F2,
Parts count
Ground Benign, 25°C
(77°F)
677 000 hours
Service life
Operating
10 year
Vibration
IEC 60068-2-6
(sine)
Operating
3 – 13.2 Hz: 1mm
13.2 – 100 Hz: 0.7 g
5.5 – 30 Hz: 1.5 g
30 – 50 Hz: 0.42 mm
50 – 500 Hz: 4.2 g**
IEC 60068-2-64
(random)
5 – 20 Hz: 2 m²/s³,
20 – 2000 Hz: – 3 dB/oct
Shock
IEC 60068-2-27
Operating
30 g, 11 ms
100 g, 6 ms**
Bump
IEC 60068-2-27
Operating
10 g, 11 ms
Packaging
Enclosure
EN 60950-1
Zinc
Fire enclosure
Dimension W x H x D
With connectors
52.5 x 100 x 101 mm
52.5 x 119 x 101 mm
Weight
0.7 kg
Degree of protection
EN 60529
Enclosure
IP 40
Cooling
Convection
* Refer to “Safety” section in User Guide.
** Might require Ethernet cables to be fastened close to the unit.
- TR-36B (88 pages)
- TD-36 (44 pages)
- TR-36 (36 pages)
- TR-36B (20 pages)
- IDW-90 AT (97 pages)
- GD-01 (206 pages)
- GD-01 (20 pages)
- MRI-128-F4G (175 pages)
- MRI-128-F4G (169 pages)
- GDW-11 (40 pages)
- GDW-11 485 (380 pages)
- Lynx Series (28 pages)
- ODW-720-F2 (36 pages)
- ODW-720-F1 (20 pages)
- ODW-720-F1 (24 pages)
- ODW-730-F2 (36 pages)
- ODW-730-F1 (24 pages)
- DDW-120 (24 pages)
- DDW-226-EX (24 pages)
- DDW-226-EX (24 pages)
- DR-270 (28 pages)
- DR Series (460 pages)
- ED-2x0 (20 pages)
- MRD-3x0 (199 pages)
- FD-80 (24 pages)
- FDV-206-1D-1S (24 pages)
- GD-01 US (24 pages)
- LD-01 (8 pages)
- IDW-90 (44 pages)
- Lynx-x10-F2G (16 pages)
- Lynx-x08-F2G-S2 (20 pages)
- MDI-110-F3x (16 pages)
- MR-2x0 (28 pages)
- ODW-642 (28 pages)
- PII PoE Injector (12 pages)
- Viper Series (977 pages)
- SDI-5xx (12 pages)
- RFI-xx (32 pages)
- SDI-8xx (16 pages)
- RFIR-xxx (24 pages)
- TD-29 (16 pages)
- SDW-5xx (24 pages)
- TD-23 (24 pages)
- TD-29P (16 pages)
- Viper 408 (20 pages)