beautypg.com

Westermo Lynx-x05-S1 User Manual

Page 7

background image

7

6643-2230

Environmental

Temperatures

Operating

–40 to +70°C (–40 to +158°F)*

Storage and transport

–50 to +85°C (–58 to +185°F)

Humidity

Operating

5 to 95 % relative humidity

Storage and transport

5 to 95 % relative humidity

Altitude

Operating

2 000 m / 70 kPa

MTBF

MIL-C217F2,
Parts count

Ground Benign, 25°C
(77°F)

677 000 hours

Service life

Operating

10 year

Vibration

IEC 60068-2-6
(sine)

Operating

3 – 13.2 Hz: 1mm
13.2 – 100 Hz: 0.7 g

5.5 – 30 Hz: 1.5 g
30 – 50 Hz: 0.42 mm
50 – 500 Hz: 4.2 g**

IEC 60068-2-64
(random)

5 – 20 Hz: 2 m²/s³,
20 – 2000 Hz: – 3 dB/oct

Shock

IEC 60068-2-27

Operating

30 g, 11 ms
100 g, 6 ms**

Bump

IEC 60068-2-27

Operating

10 g, 11 ms

Packaging

Enclosure

EN 60950-1

Zinc

Fire enclosure

Dimension W x H x D
With connectors

52.5 x 100 x 101 mm
52.5 x 119 x 101 mm

Weight

0.7 kg

Degree of protection

EN 60529

Enclosure

IP 40

Cooling

Convection

* Refer to “Safety” section in User Guide.