beautypg.com

Westermo TD-23 User Manual

Page 12

background image

12

6600-2204

Relay (optional)
Rated voltage

Up to 48 VDC

Operating voltage

Up to 60 VDC

Contact rating

50 mA @ 48 VDC

Contact resistance

8 Ω

Transmission range

≤ 3 m, depending on data rate and cable type

Function

The output follows the transmit carrier, I.e. output shorted
when carrier is ON.

Isolation to

Power, Leased Line, RS-232, RS-485/422

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm² (AWG 24 – 12)

Shielded cable

Not required

Leased Line
Electrical specification

2- or 4-wire Leased Line

Data rate

300 bit/s – 1200 bit/s

Transmission level

+3, –3, –6, –9, –10, –12, –13, –15 dBm
Transmision levels above –9 dBm are not allowed on
PTT networks only on private wires

Sensitivity reseption

–45, –33, –27, –23 dBm

Protocol

V23hdx, V23fdx

Turn around time

33 ms (half duplex)

Transmission range / Budget

30dB

Protection

Installation Fault Tolerant (up to ±60 V)

Isolation to

Power / RS-232 / RS-422/485

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm² (AWG 24 – 12)

Shielded cable

Not required