Agency approvals and standards compliance, Cleaning of the optical connectors, Maintenance – Westermo SDW-5xx User Manual
Page 7
7
6644-2214
Note. Fibre Optic Handling
Fibre optic equipment needs special treatment. It is very sensitive to dust and dirt. If
the fibre will be disconnected from the modem the protective hood on the transmitter/
receiver must be connected. The protective hood must be kept on during transportation.
The fibre optic cable must also be handle the same way.
If this recommendation not will be followed it can jeopardise the warranty.
Cleaning of the optical connectors
In the event of contamination, the optical connectors should be cleaned by the use of
forced nitrogen and some kind of cleaning stick.
Recommended cleaning fluids:
• Methyl-, ethyl-, isopropyl- or isobutyl-alcohol
• Hexane
• Naphtha
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified
conditions.
Agency approvals and standards compliance
Type
Approval / Compliance
EMC
EN 61000-6-2, Immunity industrial environments
EN 61000-6-3
1
, Emission residential environments
EN 61000-6-4
2
, Emission industrial environments
E-Mark, Road Vehicles, 10R-04 7216
6
Safety
UL 60950-1, 1st Edition
3
Marine
DNV Standard for Certification no. 2.4
4
Ex
EN 60079-0 and EN 60079-15
5
Note
1
– Applicable only for 3644-000x and 3644-0015
2
– Applicable only for 3644-0019, 3644-002x and 3644-003x
3
– Applicable only for 3644-000x (SDW-550 och SDW-550 EC)
4
– Applicable only for 3644-0001, 3644-0022 , 3644-0023, 3644-0025,
3644-0032, 3644-0033, 3644-0035
(SDW-550, SDW-532-MM-LC15, SDW-532-MM-LC2, SDW-532-SM-LC40,
SDW-532-2SM-LC15, SDW-532-2SM-LC2, SDW-532-2SM-LC40)
5
– Applicable only for SDW-5xx Ex series
6
_ Applicable only for 3644-6001 (SDW-550 E-mark)