12

6651-2221

RS-232

Electrical specification

EIA RS-232

Data rate

300 bit/s – 250 kbit/s

Protocol

Asynchronous or synchronous

Data format

9 – 12 bits in asynchronous mode
Any type in synchronous mode

Data retiming

Asynchronous mode only

Transmission range

15 m

Isolation to

Status and Power port

Connection

9-pin D-sub female (DCE)

Shielded cable

Not required, except when installed in railway applications as
signalling and telecommunications apparatus and located close
to rails*

Conductive housing

Isolated to all other circuits and housings

* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m

boundary to the rails and connected to this port.
The cable shield should be properly connected (360°) to an earthing point within 1 m from this port.

This earthing point should have a low impedance connection to the conductive enclosure of the apparatus

cabinet, or similar, where the unit is built-in. This conductive enclosure should be connected to the earthing
system of an installation and may be directly connected to the protective earth.