beautypg.com

Westermo Lynx-x08-F2G-S2 User Manual

Page 6

background image

6

6643-2220

EN 61000-4-9,
pulsed magnetic field

300 A/m

EN 61000-4-3,
radiated RF immunity

20 V/m @ (80 – 2700) MHz
1 kHz sine, 80% AM

EN 61000-4-6,
conducted RF immunity

Power port: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Ethernet: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Ethernet: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Status out/Digital in: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Status out/Digital in: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Serial ports: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Earth port: 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz

EN 55022,
radiated RF emmision,
FCC Part 15/ DNV 2.4

EN 55022/FCC Part 15/DNV 2.4, Class B / DNV bridge

EN 55022,
conducted RF emmision,

EN 55022/FCC Part 15/DNV 2.4, Class B / DNV bridge

DNV 2.4,
compass safe distance

Standard compass (5.4°/H deviation) = 15 cm
Steering/standby steering/emergency compass
(18°/H deviation) = 10 cm

Safety
Safety

UL/IEC/EN 60950-1, IT equipment

EN 60950-1,
dielectric strength

Power port to all other ports: 1.5 kVrms, 50 Hz, 1 min
Ethernet ports to all other ports: 1.5 kVrms, 50 Hz, 1 min
RS-232 port to all other ports: 1.5 kVrms, 50 Hz, 1 min
RS-422/485 port to all other ports: 1.5 kVrms, 50 Hz, 1 min

Reliability prediction
MTBF, operating

517 000 hours

Service life, operating

10 years

Climatic
Temperature, operating

–40 to +70°C (–40 to +158°F)

Temperature, storage

–50 to +85°C (–58 to +185°F)

Humidity, operating

5 to 95 % relative humidity

Humidity, storage

5 to 95 % relative humidity

Enclosure
Enclosure

Fire enclosure

Dimensions (W x H x D)

52.5 x 100 x 101 mm

Weight

0.7 kg

Degree of protection

IP 40

Cooling

Convection

Mounting

Horizontal on 35 mm DIN-rail