beautypg.com

Sfp transceivers – Westermo Lynx-x10-F2G User Manual

Page 8

background image

8

6643-2213

I/O / Relay output
Maximum voltage/current

60 VDC / 80 mA

Contact resistance

Max 30 Ω

Isolation to

All other

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm

2

(AWG 24 – 12)

I/O / Digital input

Maximum voltage/load current

60 VDC / 2 mA

Voltage levels

Logic one: >12V
Logic zero: <1V

Isolation to

All other

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm

2

(AWG 24 – 12)

Console
Electrical specification

TTL-level

Data rate

115.2 kbit/s

Data format

8 data bits, no parity, 1 stop bit, no flow control

Circuit type

SELV

Connection

2.5 mm jack, use only Westermo cable 1211-2027

SFP Transceivers

Supported transceivers
Firmware prior to 4.4.0 accepts Westermo branded
transceivers only. From 4.5.0 other transceivers are accepted with a notice and the
unit will no longer be UL approved. Temp.specifications are also depending on the
used transeivers.
Note: To comply with UL60950-1 only UL recognized SFP transceivers should be used.
Deviations
With copper transceiver 1100-0148 the specified operating temperature on Lynx
is 0 to +50ºC (32 to +122°F).
FRNT reconfiguration times can not be guaranteed with copper transceivers.