8 tube materials in atex applications – Watson-Marlow 505LA User Manual
Page 6
ATEX Directive: Watson-Marlow 505LA, 505LXA and 505LGA pumpheads User Manual
6
8 Tube materials in
ATEX applications
The following Watson-Marlow tube materials are suitable for use in ATEX applications:
l Pumpsil (platinum-cured silicone)
l Marprene
l Bioprene
l STA-PURE PCS
l STA-PURE PFL
l Neoprene
l PVC
Please note from the table below that there are limitations of length that can be used
for certain tube materials. Pumpsil cannot be used in any ATEX application above
the specified lengths listed. When using Bioprene and Marprene there is a reduction
in class suitability when they are in contact with Polymides.
Permissible length of tubing (cm) for IIB rating:
Series
Bore
(mm)
Wall
(mm)
OD
(mm)
Pumpsil
(cm)
STA-PURE
PCS* (cm)
STA-PURE
PFL* (cm) Marprene** Bioprene**
PVC
Neoprene
313DA, 501RLA, 505LA 9.6
2.4 14.4
69
69
69
unlimited
unlimited
unlimited
unlimited
313DA, 501RLA, 505LA 8.0
2.4 12.8
78
78
78
unlimited
unlimited
unlimited
unlimited
313DA, 501RLA, 505LA 6.4
2.4 11.2
89
89
89
unlimited
unlimited
unlimited
unlimited
313DA, 501RLA, 505LA 4.8
2.4
9.6
104
104
104
unlimited
unlimited
unlimited
unlimited
313DA, 501RLA, 505LA 3.2
2.4
8.0
125
125
125
unlimited
unlimited
unlimited
unlimited
313DA, 501RLA, 505LA 1.6
2.4
6.4
156
156
156
unlimited
unlimited
unlimited
unlimited
313DA, 501RLA
8.0
1.6 11.2
89
89
89
unlimited
unlimited
unlimited
unlimited
313DA, 501RLA
6.4
1.6
9.6
104
104
104
unlimited
unlimited
unlimited
unlimited
313DA, 501RLA
4.8
1.6
8.0
125
125
125
unlimited
unlimited
unlimited
unlimited
313DA, 501RLA
3.2
1.6
6.4
156
156
156
unlimited
unlimited
unlimited
unlimited
313DA, 501RLA
2.4
1.6
5.6
179
179
179
unlimited
unlimited
unlimited
unlimited
313DA, 501RLA
1.6
1.6
4.8
208
208
208
unlimited
unlimited
unlimited
unlimited
501RLA
0.8
1.6
4.0
250
250
250
unlimited
unlimited
unlimited
unlimited
501RLA
0.5
1.6
3.7
270
270
270
unlimited
unlimited
unlimited
unlimited
* If length limit exceeded for STA-PURE PCS and STA-PURE PFL, ATEX rating
reduced to IIA
** Marprene and Bioprene rated IIA when in contact with Polymides