The following tube materials can be used with 620RA pumpheads. Bore sizes range
from 6.4mm to 15.9mm, with 3.2mm wall thickness. LoadSure tube elements are
available in 12mm or 17mm bore:

Tubing: working temperature range
Marprene

5C to 80C

Bioprene

5C to 80C

Pumpsil

-20C to 80C

STA-PURE PCS

0C to 80C

STA-PURE PFL

0C to 80C

Neoprene

0C to 80C

PVC

0C to 80C

The following parameters define the boundary of the safe working envelope these
values must not be exceeded (ATEX compliance will be invalidated):

620RA pumpheads

Ambient temperature range

5C to 40C

Max peak pressure (continuous tubing) 2 bar
Max peak pressure (STA-PURE tubing) 4 bar
Max continuous speed

165 rpm (at 4 bar see below)

Max intermittent speed

265 rpm (at 4 bar see below)

Corrosion resistance

See 7 Materials

Tube life

See 5 Tube failure