Operator’s manual ebu250 – Watson-Marlow EBU250 User Manual
Page 7

Operator’s manual
EBU250
Rev.: 1.01 Date: 2007-02-20 Page 7 of 8
File:
EBU250 OM 1.01 EN.DOC
F51 NEEDLE-TYPE:
3
I 1
F47: PRINTER-SETUP
F48: RS232-SETUP
F49: BALANCE SETUP
F51: NEEDLE
F53: DRIVES ON/OFF
Fig. 6.1
F51 FOLLOW DRIVE
0
I 1
F47: PRINTER-SETUP
F48: RS232-SETUP
F49: BALANCE SETUP
F51: NEEDLE
F53: DRIVES ON/OFF
Fig. 6.2
The drive number is entered followed by
After entering drive number the nozzle should follow, the MC12 asks for a transport speed by
displaying:
F51 TRANSPORT SPEED (mm/sec): 30_
I 1
F47: PRINTER-SETUP
F48: RS232-SETUP
F49: BALANCE SETUP
F51: NEEDLE
F53: DRIVES ON/OFF
Fig. 6.3
The transport speed is the speed by which the nozzle moves up and down when NOT filling. The
speed is set in millimetres/sec.
The MC12 then asks for a fill speed by displaying:
F51 FILL SPEED (mm/sec): 30_
I 1
F47: PRINTER-SETUP
F48: RS232-SETUP
F49: BALANCE SETUP
F51: NEEDLE
F53: DRIVES ON/OFF
Fig. 6.4
The fill speed is the speed by which the nozzle moves upward while filling. The speed is set in
millimetres/sec.
The set-up menu is then shown. The purpose here is to run a test on nozzle after it has been
positioned mechanically:
F51 SET-UP (0:DOWN / 1:UP):
I 1
F47: PRINTER-SETUP
F48: RS232-SETUP
F49: BALANCE SETUP
F51: NEEDLE
F53: DRIVES ON/OFF
Fig. 6.5