Installation – Desa VTD-24N-JHB User Manual
Page 6
www.desatech.com
114370-01D
Figure 3 - Attaching Damper Clamp
Manufactured
Fireplace
Masonry
Fireplace
Damper
Damper
Clamp
Damper
Damper
Clamp
Damper
VENTING SPECIFICATIONS FOR
INSTALLATION
The fireplace chimney flue and vent must be draft-
ing properly. To check the vent for proper drafting:
Light a tightly rolled newspaper on one end and
place it at the inside front edge of the fireplace.
Observe the smoke and be sure the vent is properly
drawing it up the chimney. If the smoke spills out
into the room, extinguish the flame and remove any
obstruction until proper venting is achieved.
The chimney flue must remain open a minimum of 3"
at all times during the operation of this log set.
INSTALLING DAMPER CLAMP
Secure the damper stop clamp to the edge of the
damper as shown in Figure 3. If for any reason this
clamp doesn't work on your fireplace, another suit-
able clamp or permanent stop must be installed, or
the damper blade must be cut or removed.
MODEL
BURNER
DESCRIPTION
BTU
INPUT
MINIMUM VENT
OPENING
VTD-18N-JHB
18" Ramp
59,000
8" dia.
VTD-4N-JHB
4" Ramp
9,000
8" dia.
VTD-30N-JHB
30" Ramp
74,000
8" dia.
INSTALLATION
Continued
MINIMUM FIREBOX SIZES
MODEL
FRONT WIDTH
BACK WIDTH*
DEPTH
HEIGHT
VTD-18N-JHB
8"
1"
14"
18"
VTD-4N-JHB
9
3
/
4
"
17"
15
1
/
"
18"
VTD-30N-JHB
3"
7"
18"
18"
*At depth indicated
BURNER ORIFICE
LOG SIZE
NATURAL
INCHES
NUMBER
18"
0.1495
5
4"
0.1570
30"
0.10
19
FUEL INLET PRESSURE
SPECIFICATIONS (W.C.)
MIN.
MAX.
NG
5.5"
10.5"
Figure 2 - Technical Information Charts