Verilink PRISM 3301 Download (CG) Configuration/Installation Guide User Manual
Page 2

127 Jetplex Circle
Madison, Alabama 35758
Customer Service
888-4TxPORT, ext. 2227
800-926-0085, ext. 2227
Technical Support
(8 a.m. to 5 p.m., Central)
888-4TxPORT
800-285-2755
205-772-3770
Emergency After Hours
800-285-2755
Switch S4
1
8
7
6
5
4
3
2
Circuit Board View
Switch S1
1
8
7
6
5
4
3
2
Switch S2
1
8
7
6
5
4
3
2
Switch S3
1
8
7
6
5
4
3
2
Switch S6
Switch S5
Factory default settings are underlined.
T1 DTE
1
2
3
4
5
6
7
8
9
10
11
12
( B )
NMS
IN
( B )
NMS
OUT
12
HIGH SPEED DTE
11
10
9
8
7
6
5
4
3
2
1
T1 NET
TB1
TB2
ENET
( A )
NMS
IN
( A )
NMS
OUT
TB1
TB2
Rear Panel of TxPORT 1051 Chassis
1
2
3
4
5
6
7
8
9
10
11
12
Part Number 45-00100
Rev 2.00
S1 - Network Clock
Reference
Clock Reference S1-1
S1-2
Network Clock
Down Down
DTE Exernal
Clock
Down Up
Internal Clock
Up
Down
S1 - Network Rate
Rate
S1-3
S1-4
S1-5
56 kbps
Down Down Down
64 kbps
Down Down Up
2.4 kbps
Down Up
Down
4.8 kbps
Down Up
Up
9.6 kbps
Up
Down Down
19.2 kbps Up
Down Up
38.4 kbps Up
Up
Down
S1 - DTE Rate TxPORT
Sync Mode and Line
Rate = 56 kbps
Rate
S1-6
S1-7
S1-8
54 kbps
Down Down Down
2.4 kbps
Down Down Up
4.8 kbps
Down Up
Down
9.6 kbps
Down Up
Up
19.2 kbps Up
Down Down
38.4 kbps Up
Down Up
TxPORT Sync Mode not allowed
at Line Rates below 56 kbps.
S2
S2-1
DTE Mode
S2-2
Operational Mode
S2-3
RTS/CTS
S2-4
RTS/CTS Delay
S2-5
Loop Mode
S2-6
Reset Mode
Async (Up)
Sync (Down)
TxPORT (Up)
Standard (Down)
Forced (Up)
Normal (Down)
Long (Up)
Normal (Down)
Unidirectional (Up)
Bidirectional (Down)
Download (Up)
Normal (Down)
S2 - Boot Mode
Mode
S2-7
S2-8
Saved
Down
Down
Factory
Down
Up
Switches
Up
Down
Manager
Up
Up
S3 - NMS and SUPV Rates
Rate
NMS Rate
SUPV Rate
S3-1
S3-2
S3-3
S3-4
19.2 kbps Down Down
Down Down
1.2 kbps
Down Up
Down Up
2.4 kbps
Up
Down
Up
Down
9.6 kbps
Up
Up
Up
Up
S3 - DBU Select
Mode
S3-5
Enable
Up
Disable
Down
S3 - DBU Rate
Rate
S3-6
S3-7
S3-8
57.6 kbps Down Down Down
2.4 kbps
Down Down Up
4.8 kbps
Down Up
Down
9.6 kbps
Down Up
Up
19.2 kbps Up
Down Down
38.4 kbps Up
Down Up
S4 - NMS Address
S4-1
S4-2
S4-3
S4-4
S4-5
S4-6
S4-7
S4-8
Switch
Value
1
2
4
8
16
32
64
128
001
Up
Down Down Down Down Down Down Down
002
Down Up
Down Down Down Down Down Down
003
Up
Up
Down Down Down Down Down Down
004
Down Down Up
Down Down Down Down Down
S5 and S6 - RS-232/V.35 Setting
Switches S5 and S6 are slide switches that set the unit
to either RS-232 or V.35. Both switches must be set to
the same selection (either RS-232 or V.35).
Rear Panel Connections
Pin
T1 NET
DDS
NET*
TB1
Network/
Clock
TB2
Alarm/Power
T1 DTE
(Internal
Modem
Option)
1
Data In
Data Out
Network In
48-V Return
N/A
2
Data In
Data Out
Network In
Signal Ground N/A
3
Not Used
Not Used
Network Out
-48 VDC
N/A
4
Data Out
Not Used
Network Out
Frame Ground Modem Tip
5
Data Out
Not Used
Station Clock
Alarm Contact Modem Ring
6
Not Used
Not Used
Station Clock
Common
N/A
7
Not Used
Data In
N/A
N/A
N/A
8
Not Used
Data In
N/A
N/A
N/A
* T1 NET connector converts to DDS NET using a supplied DDS Adapter
Cable (PN 9-1001-075-1).
T
R
A
N
S
P
O
R
T
®
Do
wn
Up
S1 - DTE Rate TxPORT
Sync Mode Line Rate =
64 kbps
Rate
S1-6
S1-7
S1-8
62 kbps
Down Down Down
56 kbps
Down Down Up
2.4 kbps
Down Up
Down
4.8 kbps
Down Up
Up
9.6 kbps
Up
Down Down
19.2 kbps Up
Down Up
38.4 kbps Up
Up
Down
TxPORT Sync Mode not allowed
at Line Rates below 56 kbps.
S1 - DTE Rate TxPORT
Async Mode Line Rate
≥
56 kbps
Rate
S1-6
S1-7
S1-8
57.6 kbps Down Down Down
2.4 kbps
Down Down Down
4.8 kbps
Down Up
Up
9.6 kbps
Down Up
Up
19.2 kbps Up
Down Down
38.4 kbps Up
Down Down
For TxPORT Async Mode Line
Rates below 56 kbps, DTE Rate
must match the Line Rate.
In Standard Sync Mode Line Rate = DTE Rate; S1-6, S1-7, and S1-8 do not matter.