Switch s4, High-speed dte pinout, Switch s6 – Verilink PRISM 3001 (Standalone) (CG) Configuration/Installation Guide User Manual
Page 2: Switch s8 (t1 dte), Address switch s5, S7 bit rates (kbps), Alarm relay, Bantam jacks, Top-edge view of the 3001
T
R
A
N
S
P
O
R
T
®
1051-2 Chassis Rear Panel Pinouts
Pin
T1 D/I
T1 NET
NMS IN
NMS OUT
Alarm /Power Net/Ext. Clk
1
Data Out
Data In
Not Used
Not Used
48 V Return
Net In (Tip)
2
Data Out
Data In
Signal Ground
Signal Ground
Signal Ground Net In (Ring)
3
Not Used
Not Used
Data Out
Data Out
-48 VDC
Net Out (Tip)
4
Data In
Data Out
Data In
Not Used
Frame Ground Net Out (Ring)
5
Data In
Data Out
Signal Ground
Signal Ground
Alarm Contact Station Clk (Ring)
6
Not Used
Not Used
Not Used
Not Used
Alarm Common Station Clk (Tip)
7, 8
Chassis Ground Chassis Ground Not Applicable Not Applicable Not Applicable Not Applicable
1
61
1
1
6
1
8
1
8
NMS IN
6
NMS OUT
T1 D/I
NETWORK
1
14
13
25
DTE
PORT
48 VDC
ALARM/POWER
NTWK/EXT CLK
Switch S4
S4- 1: Network Framing
Dn: ESF
Up: D4
S4- 2: Network Coding
Dn: AMI
Up: B8ZS
S4-5: Channel Assignment - Used to
select DS0 channels (used with Switch
S7). See Table S7 Bit Rates (kbps).
S4- 8: Channel Assignment - Used to
select channel assignment mode (used
with Switch S7).
Dn: Contiguous Up: Alternate
S4 -3
S4 -4
Network LBO
Dn
Dn
0 dB
Up
Dn
-7.5 dB
Dn
Up
-15.0 dB
Up
Up
-22.5 dB
S4 -6
S4 -7
Timing Source
Dn
Dn
Internal Settings
Up
Dn
Network
Dn
Up
T1 DTE
Up
Up
High-speed port
8
6
5
4
3
2
1
D
n
U
p
7
127 Jetplex Circle
Madison, Alabama 35758
Sales and Marketing
800-926- 0085
205-772-3770
Returns/RMA
800-926-0085, ext. 2227
Technical Support
800-285- 2755
205-772- 3770
High-speed DTE Pinout
DB-25
25 - pin
A/B
Common
Name
EIA-530
25 - pin
A/B
RS-449
37-pin
A/B
V.35
34-pin
A/B
1
Frame Ground 1
1
A
7
Signal Ground 7
19
B
2 /14 Transmit
Data
2 /14 4/22
P/S
3/16 Receive
Data 3 /16
6/24
R /T
4/19
Request to
Send
4/19
7/25
C
5/13
Clear to Send
5/13
9/27
D
6/22
Data Set
Ready
6/22
11/29
E
20/23
Data Term
Ready
20/23
12/30
H
8/10
Data Carrier
Detect
8/10
13/31
F
15/12
Transmit
Clock
15/12
5/23
Y/AA
17/9
Receive Clock 17/9
8/26
V/ X
24/11
Terminal
Timing
24/11
17/35
U/ W
Switch S6
S6- 7: Used to set the multiplier with
Switch S7.
Dn:
×64
kbps
Up:
×56
kbps
S6- 8: Not used.
S6-1
S6- 2
NMS Port Rate
Dn
Dn
19200 bps
Up
Dn
9600 bps
Dn
Up
2400 bps
Up
Up
1200 bps
S6- 3
S6- 4
SUPV Port Rate
Dn
Dn
19200 bps
Up
Dn
9600 bps
Dn
Up
2400 bps
Up
Up
1200 bps
S6- 5
S6- 6
Power-up Mode
Dn
Dn
Switch Settings
Up
Dn
RAM
Dn
Up
Network Manager
Up
Up
ROM
8
6
5
4
3
2
1
D
n
U
p
7
Switch S8 (T1 DTE)
If equipped, this board is located on
the opposite side of the circuit board
shown in Figure Top-edge View of the
3001.
S8- 1: Used to set the line framing.
Dn: ESF
Up: D4
S8- 2: Used to set the line coding.
Dn: AMI
Up: B8ZS
S8- 6, S8-7, and S8- 8: Not used.
S8 -3 S8 - 4 S8 -5 DTE LBO
Dn
Dn
Dn
0 - 110 ft
Up
Dn
Dn
110 - 220 ft
Dn
Up
Dn
220 - 330 ft
Up
Up
Dn
330 - 440 ft
Dn
Dn
Up
440 - 550 ft
Up
Dn
Up
550 - 655 ft
Dn
Up
Up
>655 ft
8
6
5
4
3
2
1
D
n
U
p
7
8
6
5
4
3
2
1
Dn
Up
7
1
2
4
8
16
32
64
128
Binary values
0
0
0
0
0
0
0
0
LSB
MSB
Address Switch S5
For reference, all DIP
switches are provided with
upper and lower boxes to
check the particular user
selection. Factory default set-
tings are shown underlined.
S7 Bit Rates (kbps)
Switch
S7
w/S4- 5 down
w/S4-5 up
×56
×64
×56 ×64
0
56
64
168
192
1
112
128
280
320
2
224
256
392
448
3
336
384
448
512
4
560
640
504
576
5
672
768
616
704
6
1008
1152
728
832
7
1120
1280
784
896
8
1232
1408
896
1024
9
1344
1536
1064
1216
20 of the 24 possible bit rate configura-
tions are available through Switch S7
(and Switch S4). The missing rates are
N
×
56 and N
×
64, where N =15, 17, 21,
and 23. All 24 rate configurations are
available through software control.
This 3 -pin header straps the ACO alarm
contact. Position jumper over pins 1 and
2 for normally open operation (closes on
alarm) or over pins 2 and 3 for normally
closed operation (opens on alarm).
NO
NC
1
2
3
Alarm Relay
Top-edge View of the 3001
0
1
2
3
4
5 6
7
9
8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Alarm
S5
S4
S6
S7
Bantam Jacks
Receive signal from
the network
Monitor signal from
the network
Transmit signal
to the network
Monitor signal
from the DTE
Four front panel bantam test jacks are
provided for access to the T1 line on
the DTE side of the CSU. Two are used
for non-intrusive bridge monitoring of
the line in both directions (MON) and
two are used to insert into the line in
both directions (NET).