Port 1 and supv, 8100a rear view (standalone model), Switch s1 – Verilink 8100A (CG) Configuration/Installation Guide User Manual
Page 2: Jumper j1 port 2, Ethernet, Power/alarm, Token ring

T1
NET
1
T1
NET
2
T1
NET
3
T1
NET
4
T1
NET
5
T1
NET
6
T1
NET
7
T1
NET
8
T1
NET
9
T1
NET
12
ENET
T1
NET
10
T1
NET
11
1 2 3 4 5
1 2 3 4 5 6
2.4 AMPS
HIGH
SPEED
DTE
12
HIGH
SPEED
DTE
11
TB2 -
HIGH
SPEED
DTE
10
HIGH
SPEED
DTE
9
HIGH
SPEED
DTE
8
HIGH
SPEED
DTE
7
HIGH
SPEED
DTE
6
HIGH
SPEED
DTE
5
HIGH
SPEED
DTE
4
HIGH
SPEED
DTE
3
HIGH
SPEED
DTE
2
HIGH
SPEED
DTE
1
T1
NET
7
T1
NET
8
T1
NET
9
T1
NET
12
T1
NET
10
T1
NET
11
T1
NET
1
T1
NET
2
T1
NET
3
T1
NET
4
T1
NET
5
T1
NET
6
NMS A & NMS B, IN AND OUT, ARE NON-TELECOM (T1) CONNECTORS
Les portes d'entree/sortie NMS A & NMS B sont des connecteurs non-telecommunication (T1)
( A )
NMS
OUT
( A )
NMS
IN
( B )
NMS
OUT
( B )
NMS
IN
TB1
1 - EXT CLK
2 - EXT CLK
3 - ALARM RING
4 - ALARM TIP
5 - SIG GND
1 - +48V RTN ( B )
2 - FRAME GND
3 - -48V IN ( B )
4 - -48V IN ( A )
5 - SIG GND
6 - +48V RTN ( A )
TB2
TB1 -
TB2
1- 48V RTN
2- GROUND
3- 48V DC
4- FRAME
5- ALM RING
6- ALM TIP
1
6
1
1
6
1
6
1
6
NMS IN
1
NMS OUT
PORT 1
PORT 2
1
9
8
15
ENET
48VDC
Port 1 and SUPV
Pin
Assignment
1
Ext. Alarm - Lead At
2
Signal Ground
3
Data Out
4
Data In
5
Signal Ground
6
Ext. Alarm - Lead B
TxPORT 1051-3 Chassis Rear View
(Note: 1051-2 chassis uses DB-25 connectors on the high speed ports.
NMS
Pin
Bus IN
Bus OUT
1
Not Used
Not Used
2
Signal Ground
Signal Ground
3
Not Used
Data Out
4
Data In
Not Used
5
Signal Ground
Signal Ground
6
Not Used
Not Used
8100A Rear View
(Standalone Model)
S1 - 1 S1 - 2
TERM
1
Bit
Rate
Open
Open
38400 bps
Closed
Open
19200 bps
Open
Closed
9600 bps
Closed
Closed
2400 bps
S1 - 3 S1 - 4
TERM
2
Bit
Rate
Open
Open
38400 bps
Closed
Open
19200 bps
Open
Closed
9600 bps
Closed
Closed
2400 bps
S1 - 5 S1 - 6 NMS
Bit
Rate
Open
Open
19200 bps
Closed
Open
9600 bps
Open
Closed
2400 bps
Closed
Closed
1200 bps
S1- 7: Enables the forcing of a control board Flash
download on power-up.
Open - Normal
Closed - Forced Download
S1- 8: Enables the forcing of a Maintenance Reset on
power Open.
Open - Normal
Closed - Maintenance Rese
t
Switch S1
Factory default settings are shown underlined.
127 Jetplex Circle
Madison, Alabama 35758
Technical Support
800- 285-2755
205- 772-3770
Returns/RMA
800-285-2755, ext. 2282
Normally Open (NO) - Pins 1 and 2
Normally Closed (NC) - Pins 2 and 3
Jumper J1
Port 2
Pin
Assignment
Internal
Modem
SLIP
1
Not Used
Not Used
Control Out
2
Signal Ground
Not Used
Signal Ground
3
Data Out
Telco Tip
Data Out
4
Data In
Telco Ring
Data In
5
Signal Ground
Not Used
Signal Ground
6
Not Used
Not Used
Control In
Ethernet
Pin Circuit
ENET
3
10
11
DO-A
DO-B
DO-S
Data Out (A)
Data Out (B)
Circuit Shield
5
12
4
DI-A
DI- B
DI -S
Data In (A)
Data In (B)
Circuit Shield
2
9
1
CI-A
CI-B
CI-S
Control In (A)
Control In (B)
Circuit Shield
6
VC
Voltage Common
13
VP
Voltage Plus
14
VS
Voltage Shield
Shell
PG
Protective Ground
(Conductive Shell)
Power/Alarm
Pin
Assignment
1
48 VDC Return (+)
2
Signal Ground
3
48 VDC (-)
4
Frame Ground
5
Alarm Contact
6
Alarm Common
Token Ring
Pin
Assignment
1
Not Used
2
Not Used
3
Data Out (-)
4
Data In (+)
5
Data In (-)
6
Data Out (+)
SUPV and Port 1 are identical ports. You
cannot use both ports at the same time.
You must use either SUPV or Port 1.
(formerly TxPORT)