beautypg.com

Verilink 4019-1 (WS) Configuration/Installation Guide User Manual

Verilink Computer hardware

background image

880-501286-001-C

April 1994

Page 1 of 1

WT-1 JUMPER

DTE Receive Distance

SELECT DESIRED OPTION:

1 - 2*

0’ - 85’ *

3 - 4

85’ - 375’

5 - 6

375’ - 655’

WT-2 JUMPER

DTE Transmit Distance

SELECT DESIRED OPTION:

1 - 2 *

0’ - 85’ *

3 - 4

85’ - 375’

5 - 6

375’ - 655’

S2

Transmit (Artificial Line)

SELECT DESIRED OPTION:

15dB

0 - 1000 ‘ twisted copper

7.5dB *

1000’ - 2000’ twisted copper *

0dB

2000’ - 3000’ twisted copper or local
DS3 mux, radio, or other equipment
requiring DSX level

S1

Critical Circuitry Power

SELECT DESIRED OPTION:

SP *

Span power *

WL

Local Power Wet Loop
(CSU applies sealing current)

DL

Local Power Dry Loop
(Loop any sealing current)

NOTES:

1. * = These are the factory defaults and are those most commonly used in the field.

2. For additional installation information, refer to manual Part No. 880-500497-001.

3. FCC Reg: GIC472-16545-DE-N

FIC: O4DU9-B

4. Telco jack: DA-15 or wire-wrap

...

...

... ...

5

1

6

2

WT1

5

1

6

2

WT2

DL WL SP

S1

0 7.5 15

S2

REGENERATOR

4019-1 CSU Plug-In

Installation Worksheet

D