beautypg.com

1558d option switch configuration information, Option switch s2, pos. 1 - 8, Option switch s1, pos. 1 - 8 – Verilink 1558D (CG) Configuration/Installation Guide User Manual

Page 3: Option switch s3, pos. 1 - 8, Option switch s4, pos. 7 - 10

background image

Option Switch S4, Positions 1 - 6 (speed selection)

Pos

1

Pos

2

Pos

3

Pos

4

Pos

5

Pos 6

OFF

(64Kb)

Pos 6 ON

(56Kb)

DS0

OFF

OFF

OFF

OFF

OFF

1536

1344

24

OFF

OFF

OFF

ON

OFF

1472

1288

23

ON

OFF

OFF

ON

OFF

1408

1232

22

OFF

ON

OFF

ON

OFF

1344

1176

21

ON

ON

OFF

ON

OFF

1280

1120

20

OFF

OFF

ON

ON

OFF

1216

1064

19

ON

OFF

ON

ON

OFF

1152

1008

18

OFF

ON

ON

ON

OFF

1088

952

17

ON

ON

ON

ON

OFF

1024

896

16

OFF

OFF

OFF

OFF

ON

960

840

15

ON

OFF

OFF

OFF

ON

896

784

14

OFF

ON

OFF

OFF

ON

832

728

13

ON

ON

OFF

OFF

ON

768

672

12

OFF

OFF

ON

OFF

ON

704

616

11

ON

OFF

ON

OFF

ON

640

560

10

OFF

ON

ON

OFF

ON

576

504

9

ON

ON

ON

OFF

ON

512

448

8

OFF

OFF

OFF

ON

ON

448

392

7

ON

OFF

OFF

ON

ON

384

336

6

OFF

ON

OFF

ON

ON

320

280

5

ON

ON

OFF

ON

ON

256

224

4

OFF

OFF

ON

ON

ON

192

168

3

ON

OFF

ON

ON

ON

128

112

2

ON

ON

ON

ON

ON

64

56

1

Option Switch S2, Pos. 1 - 8

Position

Switch S2 Description

1

OFF = CSU Mode, Enabled
ON = CSU Mode, Disabled

2

OFF = Path Revert, Disabled
ON = Path Revert, Enabled

3,4

NET A LBO Value
0.0 db OFF, OFF
7.5 db OFF, ON
15.0 db ON, OFF
22.5 db ON, ON

5,6

NET A LBO Value
0.0 db OFF, OFF
7.5 db OFF, ON
15.0 db ON, OFF
22.5 db ON, ON

7,8

OFF, OFF =Network Clocking
OFF, ON = Network Clocking
ON, ON = Internal Clocking
ON, OFF = External DTE Clocking

Option Switch S1, Pos. 1 - 8

Position

Description

1

OFF = Card Function, Slave
ON= Card Function, Master

2,3

OFF,OFF = Boot from Switches
OFF,ON = Boot from Manager
ON,OFF = Boot from RAM
ON,ON = Boot from ROM

4

OFF = ARM from ROM
ON= ARM from RAM

5

OFF = Enable Frame Error Alarm
ON = Disable Frame Error Alarm

6

OFF = LOS, Enabled
ON= LOS, Disabled

7

OFF = NET/A, B8ZS
ON = NET/A, AMI

8

OFF = NET/B, B8ZS
ON = NET/B, AMI

Option Switch S3, Pos. 1 - 8

*APS Mgr.

Unit Pos.

NET A/B

Address

Pos

1

Pos

2

Pos

3

Pos

4

Pos

5 - 8

1.01

1/2

OFF

OFF

OFF

OFF

OFF

1.02

3/4

ON

ON

OFF

OFF

OFF

1.03

5/6

ON

OFF

ON

OFF

OFF

1.04

7/8

ON

ON

ON

OFF

OFF

1.05

9/10

ON

OFF

OFF

ON

OFF

1.06

11/12

ON

ON

OFF

ON

OFF

Option Switch S4, Pos. 7 - 10

Position

Switch S4 Description

7

OFF = Contiguous DS0s
ON = Alternate DS0s

8

OFF = Control Lines (CTS, DSR,CD) are set on
ON = Control Lines follow (DSR follows T1 sync, CTS follows RTS, and CD fol-
lows T1 density status)

9

OFF = Data Invert Disabled
ON = Data Invert Enabled

10

Spare, Not Used

1558D Option Switch Configuration Information