4
A S 4 2 0 R e f e r e n c e M a n u a l
Specifications
Generic Interface Requirements (120
Ω
Ω
Ω
Ω
and 75
Ω
Ω
Ω
Ω
)
E1 Interface
Line Rate:
2.048 Mbps (± 32 ppm)
Framing:
ITU-T G.704 (with or without CRC-4) G.703
Line Code:
HDB3
Input Level:
E1 to 6 decibels
Pulse Width:
244 (± 41) nanoseconds at half amplitude
Pulse Afterkick:
10 to 30 percent of pulse peak
T1 Interface
Line Rate:
1.544 Mbps (± 32 ppm)
Framing:
D4 or ESF
Line Code:
AMI or B8ZS
Input Level:
0 to -36 decibels
Pulse Width:
344 (± 45) nanoseconds at half amplitude
Pulse Afterkick:
10 to 30 percent of pulse peak
120
Ω
Ω
Ω
Ω
Termination
Interface:
RJ-48C
Impedance:
120
Ω
, balanced
Output Level:
3.0 (± 0.3) volts (base-to -peak)
75
Ω
Ω
Ω
Ω
Termination
Interface:
BNC - coax
Impedance:
75
Ω
, unbalanced
Output Level:
2.37 (± 0.24) volts (base-to -peak)
E1 Equipment Interface
N
×
64 kbps rate...
for unframed E1: N = 32;
for framed E1 without CAS: N = 1 to 31;
for framed E1 with CAS: N =1 to 15 and 17 to 31
120
Ω
Ω
Ω
Ω
Termination
Interface:
RJ-48C
Impedance:
120
Ω
, balanced