Configuring the Jumpers
ECON
Page 3.2
For additional flexibility, your thermostat has three configurable
outputs. These outputs are designed to have different functions
depending on how the jumpers are set (below).
Each output, labeled MISC1, MISC2, and MISC3 may be set for one
of the six choices available.
In the diagram below, the MISC3 jumper has been set for HUM*
(humidification) operation, the MISC2 jumper has been set for
DEHUM* (dehumidification) operation, and the MISC1 jumper has
been set for PROG (programmable) operation.
NEVER PUT MORE THAN
ONE JUMPER ON THE SAME
MISC JUMPER BLOCK!
DOING SO MAY DAMAGE
YOUR THERMOSTAT AND
VOID THE WARRANTY.
MISC3
MISC3
OK
W3
PROG
HUM
DEHUM
MISC3
MISC2
MISC1
Y2
(MISC1
ONLY)
CAUTION
*The Humidity Module (sold separately) must
be installed to operate a humidification
and/or dehumidification system.