beautypg.com

Installing heater, Warning, Caution – Desa CGB35P User Manual

Page 13

background image

13

100352

INSTALLING

HEATER

Continued

CHECKING GAS CONNECTIONS

Figure 8 - Manual Shutoff Valve

PO

On Position

Off Position

Pressure Testing Gas Supply Piping System

Test Pressures In Excess of 1/2 PSIG

1. Disconnect heater and its individual manual shutoff valve from gas supply

pipe. Pressures in excess of 1/2 PSIG will damage heater regulator.

2. Cap off open end of gas pipe where manual shutoff valve was connected.
3. Pressurize supply piping system by either using compressed air or opening

propane supply tank valve.

4. Check all joints of gas supply piping system. Apply mixture of liquid soap and

water to gas joints. Bubbles forming show a leak.

5. Correct all leaks at once.

Test Pressures Equal To or Less Than 1/2 PSIG

1. Close manual shutoff valve (see Figure 8).
2. Pressurize supply piping system by either using compressed air or opening

propane supply tank valve.

3. Check all joints from propane supply tank to manual shutoff valve. Apply

mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4. Correct all leaks at once.

Pressure Testing Heater Gas Connections

1. Open manual shutoff valve (see Figure 8).
2. Open propane supply tank valve.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from manual shutoff valve to control valve on heater. Apply

mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

5. Correct all leaks at once.
6. Light heater (see Operating Heater, pages 20 through 22). Check the rest of the

internal joints for leaks.

7. Turn off heater (see To Turn Off Gas to Appliance, page 22).

Continued

WARNING

Test all gas piping and connections for leaks after install-
ing or servicing. Correct all leaks at once.

WARNING

Never use an open flame to check for a leak. Apply a
mixture of liquid soap and water to all joints. Bubbles
forming show a leak. Correct all leaks at once.

CAUTION

Make sure external regulator has been installed be-
tween propane supply and heater. See guidelines under
Connecting to Gas Supply, page 11.

This manual is related to the following products: