MANTEL CLEARANCES

In addition to meeting noncombustible material

clearances, you must also meet required clearances

between fireplace openings and mantel shelf on

each side of the fireplace. If you do not meet the

clearances listed below, you will need a hood.
Determining Minimum Mantel Clearance

If you meet minimum clearance between mantel

shelf and top of fireplace opening, a hood is not

required (see Figure 6, page 10).
Determining Minimum Mantel Clearance
When using a Hood

If minimum clearances in Figure 6, page 11 are not

met, you must have a hood. When using a hood

there are still certain minimum mantel clearances

required. Follow minimum clearances shown in

Figure 7, page 10 when using hood.

NOTICE: Surface temperatures

of adjacent walls and mantels be-

come hot during operation. Walls

and mantels above the firebox

may become hot to the touch.

If installed properly, these tem-

peratures meet the requirement

of the national product standard.

Follow all minimum clearances

shown in this manual.

NOTICE: If your installation does

not meet the minimum clear-

ances shown, you must do one

of the following:

• operate the logs only with the

flue damper open

• raise the mantel to an accept-

able height

• remove the mantel

FLOOR CLEARANCES

A. If installing appliance on the floor level, you

must maintain the minimum distance of 14"

to combustibles (see Figure 8).

B. If combustible materials are less than 14" to

the fireplace, you must install appliance at

least 5" above the combustible flooring (see

Figure 9).

INSTALLATION

Continued

Figure 8 - Minimum Fireplace Clearances

If Installed at Floor Level

Figure 9 - Minimum Fireplace Clearances

Above Combustible Flooring

14"

Min.

Combustible

Material

Noncombustible Material

Hearth

5"

Min.

Combustible

Material

INSTALLING HEATER ASSEMBLY

CAUTION: Do not remove the

data plates attached to the heater

base assembly. The data plates

contain important warranty and

safety information.

WARNING: If installing in a

sunken fireplace, special care

is needed. You must raise the

fireplace floor to allow access to

heater control panel. This will in-

sure adequate air flow and guard

against sooting and controls be-

ing damaged. Raise fireplace floor

with noncombustible material.

Make sure material is secure.

CAUTION: Do not pick up

heater assembly by the logs. This

could damage heater. Only han-

dle base assembly by grates.

IMPORTANT:

Make sure the heater burner is level.

If heater is not level, heater will not work properly.