Maintenance – Tri Tool 576AC Sever Machine User Manual
Page 9

9
Model 576AC SEVERMASTER
TM
92-0676 : Rev. 070222
All components should be cleaned and coated with a light film of oil prior to use. Use
a clean, non-detergent oil, preferably SAE 10 (90 SSU) or lighter.
The air supply for the Model 576AC (pneumatic drive) should include an adequate
filter, regulator and lubricator (FRL).
If the Model 576AC is operated in such a manner that the tool holder collect debris
while cutting, the tool holder and the slides should be cleaned after each cutting
operation.
Tool life may be severely shortened, unless chips and/or other debris that have been
deposited on the cutting head during the machining operation are removed.
RECOMMENDED MAINTENANCE SCHEDULE
Daily
Wipe the unit down and spraying with rust preventative under severe humidity
conditions.
Visually inspect for loose screws, missing screws, damage, etc.
Every 20 hours
Lubricate the male and female tool holder slides.
Every 40 hours
Thoroughly clean and lubricate main gear, drive gear, male and female tool
slides, and tripper bracket assembly.
STORAGE
When the Model 576AC is to be stored or if it will remain out of service for a
significant period of time (30 days or more), it should be thoroughly cleaned,
lubricated and sprayed with a rust preventative prior to storage.
MAINTENANCE