Model 214B ID Tracking Module (IDTM) Kit

92-1504 : Orig. 140627

MAINTENANCE

RECOMMENDED MAINTENACE SCHEDULE

Daily after operation

Wipe the unit down and spray with rust preventative under severe humidity

conditions.

Visually inspect for loose screws, missing screws, damage, etc.

Every 20 hours of actual operation

Disassemble the unit and wipe clean and lubricate the Slide Rails with a light

film of lubricant.

Excess lubricant will collect grit and/or chips and tend to cause

jamming and/or damage to the Slide Rails.

STORAGE

If the ID Tracking Module is to be stored or if it will be out of service for 30 days

or more, it should be thoroughly cleaned, lubricated and sprayed with a rust

preventative prior to storage.