4.1.1 Indication of collector temperatures
4.1.2 Indication of tank temperatures
4.1.3 Indication of sensor 3 and sensor 4
4.1.4 Indication of other temperatures
4.1.5 Operating hours counter
Displays the current collector temperature.
• COL : collector temperature (1-collector-system)
COL:
Collector temperature
display range: -40 ... +482 °F
Displays the current tank temperature.
• TST : tank temperature (1 relay)
• TSTL/U: tank temperature (2 relays)
TST:
Tank temperatures
Display range: -40 ... +482 °F
Displays the current temperature of the corresponding
additional sensor (without control function).
• S3
: temperature sensor 3
• S4
: temperature sensor 4
Note:
S3 and S4 are only indicated if the temperature sensors
are connected (shown).
S3, S4:
Sensor temperatures
Display range: -40 ... +482 °F
Displays the current temperature of the connected sensor.
TRF:
other measured
temperatures
Display range: -40 ... +482 °F
h P1, h P2:
Operating hours counter
Display channel
The operating hours counter adds up the solar operating
hours of the respective relay (h P). Completed hours are
shown on the display and may be reset back to 0. Select the
operating hours channel (h P). The center button for approx.
2 seconds in order to get back into the RESET-mode of the
counter. The display-symbol is flashing and the operating
hours will be set to 0. Press the center button again to save
the adjustment.
In order to finish the RESET-procedure, the button
must
be pressed in order to confirm.
In order to interrupt the RESET-procedure, no button
should be pressed for about 5 seconds. The controller re-
turns automatically into the indicaton mode.
4.1.6 Measuring Collected Energy
OHQM:Energy Collection
Measuring
Adjustment range: OFF ... ON
Factory setting: OFF
The unit may be used in conjunction with a flow meter for
energy collection calculations. This option is activated in the
channel OHQM.
The parameters of the flowmeter (l/min) must be adjusted
in the channel FMAX. Antifreeze type and concentration
of the heat transfer medium are indicated on the channels
MEDT and MED%.
FMAX:
Volume flow in l/min
Adjustment range 0 ... 20
in steps of 0,1
Factory setting 6,0