Specifications, Accessories, Wiring diagram – Desa VTDMV24PA User Manual
Page 17

www.desatech.com
114926-01B
17
SPECIFICATIONS
This appliance has been design certified to ANSI ZZ1.60-2003 and CSA 2.26-2003 Decorative Gas
Appliances for Installation in Solid Fuel Burning Fireplaces by OMNI Test Laboratories.
VTDMV18NA
VTDMV18PA
VTDMV24NA
VTDMV24PA
Btu (Variable)
36,000/53,000
35,000/45,000
36,000/53,000
35,000/45,000
Type Gas
Natural Gas Only Propane/LP Only Natural Gas Only Propane/LP Only
Ignition
Piezo
Piezo
Piezo
Piezo
Manifold Pressure 3.5" W.C.
10" W.C.
3.5" W.C.
10" W.C.
Inlet Gas Pressure (in. of water)
Maximum
10.5" W.C.
14" W.C.
10.5" W.C.
14" W.C.
Minimum*
5.0" W.C.
11" W.C.
5.0" W.C.
11" W.C.
* For purpose of input adjustment
Purchase these appliances from your local dealer.
If they can not supply these accessories, call DESA
at 1-866-672-6040 for referral information. You
can also write to the address listed on the back
page of this manual.
EQUIPMENT SHUTOFF VALVE
GA5010
Equipment shutoff valve with 1/8" NPT tap. Fits
1/2" pipe.
FIREPLACE HOOD
Black - GA6050
Brass - GA6052
Antique Brass - GA6053
Helps deflect heat away from mantel or wall above
fireplace. Fits opening 28" to 48" wide.
RECEIVER AND HAND-HELD
REMOTE CONTROL KIT - GHRCB
Allows the gas log heater to be turned on and off
using a hand-held remote control.
CLEANING KIT - GCK
(Not Shown)
Your vented gas appliance requires regular cleaning
and maintenance to prevent performance problems.
This kit gives you the tools and instructions to make
it easy to clean all critical areas of your appliance.
DAMPER CLAMP - GA6080
(Not Shown)
Permanently opens chimney flue damper for
vented operation.
ACCESSORIES
LAVA ROCK - GA6060
(Not Shown)
Order when additional rock is desired (1.8 lb. bag)
WIRING DIAGRAM
When Using Remote
Thermopile
To Remote
Receiver