CLEARANCES
Minimum clearances in inches to combustible materials are
G: Top 0
K: Side 0
L: Bottom 0
M: Rear 1
Clearance M between the rearmost part of the refngerator and
the wall behind the refrigerator
Clearance N on top of the condenser is related to the
minimum’ventilation height
See Fig 11 and examples below
Fig. 11
Refrigerator Overall Installation
Recess Distance between
model dimensions dimensions
dimensions
top of condenser to
top of refrigerator
Height Width
Depth Height
Width Depth Height Width
Depth
A B C h
W
d H W D e
RM360 30 3/8 21 11/16 22 1/16 29
20 1/4 20 3/16 29 3/4 20 1/2
21 3/16 1 1/4
RM460 32
23 24 11/16 32 1/8 21 9/16 22 3/4 32 5/16 21 13/16 23 3/4 1 1/4
RM660 40 13/16 23 24 11/16 40 21 9/16 22 3/4 40
21 13/16 23
1 1/4
RM760 52 23 24 11/16 51 3/16 21 9/16 22 3/4 51 3/8 21 13/16 23 3/4 1/8
RM1300 57 15/16 24 15/16 24 11/16 57
23 7/16 22 3/4 57 1/2 23 13/16 23 3/4 1/8
EXAMPLES
The clearance N for the RM360 model
IS
derived at in the
following way
Installation with upper and lower side vents
N=Minimum ventilation height 37 minus installation height
29 9/1 6 plus distance between condenser top and refrige-
rator top 1 1/4
N=37-29 9/16+1 1/4=8 11/16
Installation with roof vent and lower side vent
N=Minimum ventilation height 31 minus installation height
29 9/1 6 plus distance between condenser top and refrigerat-
or top 1 1/4 plus distance between roof surface and roof
vent cap 5 1/4
N=31-29 9/16+1 1/4+5 1/4=7 15/16
Fig. 12
8