Specifications – Studio Technologies AN-2 User Manual
Page 11

AN-2 User Guide
Issue 3
Studio Technologies, Inc.
Page 13
Verification of the specifications is accom-
plished by standard procedures with the
exception of the “noise” and “THD” mea-
surements. Since the outputs are combs,
P1 (stereo width) should be rotated to give
the maximum possible output for the
frequency chosen. This measurement
becomes the reference level below which
the noise should measure 70dB. THD
should be measured in the same way.
Specifications
Mounting
One space in a standard 19-inch (48.3cm) rack
AC Mains Requirements
100 to 125Vac or 200 to 250Vac, switch selectable,
50/60Hz, 10 watts
Fuse
0.5A for 115V, 0.25A for 230V; units shipped to
North America use 3AG type; units shipped outside
North America use 5 x 20mm type
Connectors
Input: 3-pin XLR-type female, pin 3 hot
Outputs: 3-pin XLR-type male, pin 3 hot
Input
Balanced bridging, differential amplifier
Input Impedance
100k ohms, balanced
50k ohms, unbalanced
Maximum Input Level
+20dBm (re 0.775V RMS)
Frequency Response
±1dB, 30Hz to 15kHz, delay section
±1dB, 30Hz to 30kHz, direct section
Dynamic Range
90dB
Noise
70dB below operating level
Gain
8dB
Outputs
Balanced, differential amplifiers
Output Impedance
100 ohms
Maximum Output Levels
+26dBm into 10k ohms balanced (re 0.775V RMS)
+24dBm into 600 ohms balanced (re 0.775V RMS)
+22dBm into 10k ohms unbalanced (re 0.775V RMS)
+20dBm into 600 ohms unbalanced (re 0.775V RMS)
Distortion
Less than 0.2% at maximum operating level