Step four operation – SOMFY SUNIS INDOOR WIREFREE RTS SUN SENSOR User Manual
Page 3

STEP FOUR OPERATION
DEMONSTRATION MODE
The Sunis WireFree RTS Light Sensor cans be operated in either
Demonstration Mode (temporary) or Standard (default) mode.
1. Press and hold MODE BUTTON until LED indicator blinks (color red)
LED will continue to blink for approx. 30 seconds then extinguish.
(See Figure 5)
2. If necessary, adjust sun sensitivity (threshold) setting (refer to STEP 3. [4 & 5] )
LED will blink during this mode. Should LED indicator extinguish prior to final setting, simply press the
mode button momentarily to reactivate blinking LED indicator.
3. Sunis RTS light sensor will send a "DOWN" command to the RTS receiver or motor after 5 seconds of sensing light
within the set threshold.
4. Sunis RTS light sensor will send a "UP" command to the RTS receiver or motor IMMEDIATELY after sensing light that
HAS NOT reached (or below) the set threshold.
Note:
1. Sunis light sensor will automatically default to standard operating mode after 3 minutes.
2. Rotating the Sun Sensitivity Selector to a FULL COUNTER CLOCKWISE (-) position will simulate sun
if no sun is present. It is not recommended to leave the selector (Threshold setting) in this position.
*
Standard operating mode (default) employs output response time delays.
1. Refer to STEP 3. [1-5] (Setting the Light (Sun) Sensitivity Threshold)
2. Sunis RTS light sensor will send a "DOWN" command to the RTS receiver or motor after 5 Minutes of sensing light
within the set threshold.
3. Sunis RTS light sensor will send a "UP" command to the RTS receiver or motor after 30 Minutes of sensing light that
HAS NOT reached (or below) the set threshold.
GREEN LED: INDICATES SUN (Light) WITHIN THRESHOLD SETTING
RED LED: INDICATES SUN (Light) BELOW THRESHOLD SETTING
Demonstration mode reduces the standard operating time delays,
permitting almost instantaneous operating/output response from the
Sunis light sensor. This mode facilitates initial light sensitivity (threshold)
settings and quickly demonstrates the operation of the motorized end product.
STANDARD OPERATING MODE
Note: LED indicator light will remain illuminated for approx. 15 seconds. To confirm
present light level, momentarily press the mode button to illuminate the LED indicator light.
TI N B Y
™
Sunis WireFree RTS Light Sensor Programming/Operating/Installation Instructions
On/Off
Selector Switch
Control
Setting Panel
Mode Button
*
Sun
Sensitivity
Selector
LED
Indicator
FIGURE 5
P.3 Rev2.
Note: The Sunis WireFree RTS light sensor is capable of providing control in accordance to light level conditions only.
Once a command is sent, the Sunis will not send another command until there is a change in light condition.