Setting the sensor sensitivity (threshold), Operation, Setting temperature sensitivity – SOMFY THERMO SUNIS INDOOR WIREFREE RTS SUN SENSOR User Manual
Page 3: Standard operating mode (default mode)
Function Selector
FIGURE 6
ON/OFF
Sun/Temp
Selector Switch
SETTING THE SENSOR SENSITIVITY (THRESHOLD) -
SETTING TEMPERATURE SENSITIVITY
1. Carefully remove rear cover of the Thremosunis sensor exposing
Control Setting Panel (See Figure 5).
2. Slide the ON/OFF Selector Switch to the ON or position. Sun
LED Indicator will illuminate for 5 seconds and then extinguish.
3. Momentarily press the Mode Button. Temperature LED Indicator
will illuminate for approximately 15 seconds to indicate
present threshold setting.
NOTE: LED Indicator light will remain illuminated for approximately 15
seconds. Should the LED indicator light extinguish prior to establishing the
temperature sensitivity (threshold) setting, simply press the Mode Button
momentarily to reactivate LED light.
4. Using a small screw driver or similar device, rotate the Temperature Sensitivity Selector
to the fully CLOCKWISE (+) position. Temperature LED Indicator will remain illuminated
red color (See Figure 5).
5. Slowly rotate the Temperature Sensitivity Selector COUNTER CLOCKWISE (-) until the LED Indicator illuminates to a green color. A green
colored LED indicates the present temperature value (threshold). At this value (threshold) the Thermosunis sensor will provide the
necessary RTS command as selected with the Function Selector Switch (for details reference Function Selector Switch below).
GREEN LED: INDICATES TEMPERATURE WITHIN THRESHOLD SETTING
RED LED: INDICATES TEMPERATURE BELOW THRESHOLD SETTING
Mode Button
Function Selector
Switch
FIGURE 5
On/Off
Sun/Temp
Selector Switch
Temperature
LED
Indicator
Temperature
Sensitivity
(Threshold)
Selector
Control
Setting Panel
(-)
Less
Heat
OPERATION:
STANDARD OPERATING MODE (DEFAULT MODE)
Standard operating mode (default) employs output response time delays.
1. Slide the Sun/Temp Selector Switch to the desired setting (See Figure 6).
= Activation of Window Covering via Sunlight only
= Activation of Window Covering via Temperature & Sunlight
2. Adjust Sunlight and Temperature Sensitivity (threshold) (Refer to Setting
Sensor Sensitivity (threshold) instructions pgs 2 & 3).
3. Slide the Function Selector Switch to provide the necessary RTS output commands
to the window covering. (see chart below for RTS output command modes)
the
*Command Mode 1
Go to Down Limit
or Sensor Location
Go to Up Limit
Go to "my” Position
Go to Up Limit
Go to Down Limit
Go to "my” Position
my
my
Command Mode 2 Command Mode 3
After 5 Minutes
After 30 Minutes
1
2
3
(within threshold)
(below threshold)
Switch
1 2 3
Commands Modes
= Sunlight/Temp sensor within the set “Threshold.” Thermosunis will provide an RTS command after approximately 5 minutes of sensing
within the set threshold.
= Sunlight/Temp sensor below the set “Threshold.” Thermosunis will provide an RTS command after approximately 30 minutes of sensing
below the set threshold
*When selected for use with Exterior Rolling Shutter or Exterior Shade Applications, whereby the window covering is mounted externally to the window and Thermosunis sensor, the
window covering will travel to location of sensor only. It is suggested that (Mode 1) is used to command no more than (1) window covering per sensor.
*When selected for use with Interior Window Coverings, the Thermosunis sensor will provide RTS commands to preset window covering limits = (Go to Down Limit)
= (Go to Up Limit).
© Copyright Somfy Systems, Inc. 1/2010
PAGE 3 REV 5
(+)
More Heat
Requires
OR
P-0004