503108 RS-232 INTERFACE

S1-3 on = send switch changes as “X”

messages as other controllers
alter router

S1-3 off = only respond to inquiries from

host

The 503108 is shipped with S1-3 in the on position.

S1-4 on = send XON / XOFF to host if

buffer fills

S1-4 off = do not send XON / XOFF

The 503108 is shipped with S1-4 in the on position.

S1-5 on = host mode
S1-5 off = terminal mode

The 503108 is shipped with S1-5 in the on position.

An 8 position DIP switch inside the module (S2)
sets the system size.

S2-1,2,3 Levels
1 Level =1 off

2 off

3 off

2 Levels =

1 on

2 off

3 off

3 Levels =

1 off

2 on

3 off

4 Levels =

1 on

2 on

3 off

5 Levels =

1 off

2 off

3 on

6 Levels =

1 on

2 off

3 on

7 Levels =

1 off

2 on

3 on

8 Levels =

1 on

2 on

3 on

S2-4,5,6 Number of outputs
8 Outputs =

4 off

5 off

6 off

16 Outputs =

4 on

5 off

6 off

24 Outputs =

4 off

5 on

6 off

32 Outputs =

4 on

5 on

6 off

40 Outputs =

4 off

5 off

6 on

48 Outputs =

4 on

5 off

6 on

56 Outputs =

4 off

5 on

6 on

64 Outputs =

4 on

5 on

6 on

S2-4,5,6 are not used on 12 input systems

S2-7 on = 12 input systems
S2-7 off = 8 or 16 inputs
S2-8 must be off off for 12 input systems
S2-8 off = 8 inputs
S2-8 on = 16 inputs

INSTALLATION

The RS-232 serial control option is normally
installed at the factory. If the 503108 module is
ordered separately, it should be plugged into the
left-most position in the router frame. In multi-frame
systems, the 503108 can be installed in any frame.

Serial connections. Connection is via a 9 pin
female D connector on the rear of the frame. The
pin connections for this connector are as follows:

Pin 1 Ground
Pin 2 Transmit - output (to receive - input)
Pin 3 Receive + input (to transmit + output)
Pin 4 Ground
Pin 5 No connection
Pin 6 Ground
Pin 7 Transmit + output (to receive + input)
Pin 8 Receive - input (to transmit - output)
Pin 9 Ground

When used for RS-232C control, pins 3 and 7 are
not connected.

The 503108 is normally configured at the factory
for RS-232 interface. RS-232 is also available. It
is possible to change from RS-232 to RS-422 (or
RS-422 to RS-232) in the field. Refer to the circuit
description for additional details and contact SVS
to obtain the required parts.

The 503108 has two DIP switches. A 5 position
DIP switch on the front edge of the module (S1)
sets the data rate and communication mode. The
settings for S1 are as follows:

S1-1,2 communication speed
1.2K Baud =

1 off

2 off

9.6K Baud =

1 on

2 off

38.4K Baud =

1 off

2 on

115.2K Baud =

1 on

2 on

The 503108 is shipped set to 9600 baud.