1. Introduction

Sensoray’s Model 328 PCI to PC104-Plus Adapter allows testing PCI boards using the PC104-Plus bus
system. PCI board can be placed in the system outside of the PC104-plus stack, perpendicular to the
board. This position allows more PC104-plus modules to be stacked on the top. The PCI slot can be
configured as slot 1, 2, 3 or 4, using removable jumper plugs.

2. Specifications

Parameter

Specification

Bus

PC104-Plus to 32-bit PCI

Slot configuration

Slot 1 to 4, jumper plugs

PCI board mounting

Standard 32-bit PCI Connector

Dimensions

5 x 3-5/8 inches

Operating temperature

-40

°

C to +85

°

C

3. Installation

3.1. Installation

Power down the PC104-Plus system. Plug the Model 328 adapter into a PC104-plus slot. Configure
adapter for slot1 to4 (follow instructions). Plug in the board under test into the 328 adapter. Power up
the PC104-Plus system.

3.2. Configuration

Each module in PC104-Plus system shall be properly configured to prevent conflicts. The following
table shows the appropriate jumper setting and signals used for each module in the stack.

Example

: For Slot1 install jumpers IDSEL0, REQ0, GNT0, CLK0 , INTA only,

For Slot2 install jumpers IDSEL1, REQ1, GNT1, CLK1 , INTB only.

MODULE SLOT

SELECTION JUMPERS

1

IDSEL0

REQ0

GNT0

CLK0

INTA

2

IDSEL1

REQ1

GNT1

CLK1

INTB

3

IDSEL2

REQ2*

GNT2*

CLK2

INTC

4

IDSEL3

REQ2*

GNT2*

CLK3

INTD

* NOTE1: Because module slot 3 and 4 share REQ2/GNT2, they cannot both be master devices.