Introduction, Specifications, Installation – Sensoray 327 User Manual
Page 4: Technical support

Sensoray Model 327 Instruction Manual
5
1. Introduction
Sensoray’s Model 327 PCI to PC104-Plus Adapter allows testing PCI boards using the PC104-Plus bus
system. PCI board can be placed in the PC104-plus stack, in a parallel plane to the board. This position
allows make a compact package. Custom hold-down bracket secures PCI plug-in board in the slot. The
PCI slot can be configured as slot 1, 2, 3 or 4, using removable jumper plugs.
2. Specifications
Parameter
Specification
Bus
PC104-Plus to 32-bit PCI
Slot configuration
Slot 1 to 4, jumper plugs
PCI board mounting
Standard 32-bit PCI right angle Connector, custom bracket
Dimensions
5 x 3-5/8 inches
Operating temperature
-40
°
C to +85
°
C
3. Installation
3.1. Installation
Power down the PC104-Plus system. Plug the Model 327 adapter into a PC104-plus slot. Configure
adapter for slot1 to4 (follow instructions). Plug in the board under test into the 327 adapter and attach
custom hold-down bracket. Power up the PC104-Plus system.
3.2. Configuration
Each module in PC104-Plus system shall be properly configured to prevent conflicts. The following
table shows the appropriate jumper setting and signals used for each module in the stack.
Example
: For Slot1 install jumpers IDSEL0, REQ0, GNT0, CLK0 , INTA only,
For Slot2 install jumpers IDSEL1, REQ1, GNT1, CLK1 , INTB only.
MODULE SLOT
SELECTION JUMPERS
1
IDSEL0
REQ0
GNT0
CLK0
INTA
2
IDSEL1
REQ1
GNT1
CLK1
INTB
3
IDSEL2
REQ2*
GNT2*
CLK2
INTC
4
IDSEL3
REQ2*
GNT2*
CLK3
INTD
* NOTE1: Because module slots 3 and 4 share REQ2/GNT2, they cannot both be master devices.
4. Technical Support
For technical support contact Sensoray Company, Inc.
Tel: (503) 684-8005
Fax:
(503) 684-8164
E-mail: [email protected]
http://www.sensoray.com