beautypg.com

Storage, Engine, Pump – DeVillbiss Air Power Company Devap DVH3000 User Manual

Page 16: Pressure washer

background image

16- ENG

A16091

ENGINE

Consult the Engine Owners Manual for
the manufacturer's recommendations
for storage.

PUMP

The manufacturer recommends using
a pump protector/winterizer, such as
DP80, when storing the unit for more
than 30 days and/or when freezing
temperatures are expected. If a pump
protector/winterizer is not available,
RV antifreeze or windshield washer
fluid needs to be run through the
pump as outlined in the steps below.
NOTE: Using a pump protector/
winterizer, RV antifreeze or windshield
washer fluid is to provide proper
lubrication to the internal seals of the
pump regardless of temperature or
environment.
1. Obtain a funnel, 6 oz. of RV

antifreeze or windshield washer
fluid, and 16–36" of garden hose
with a male hose connector
attached to one end.

Risk of property
damage. Use only

RV antifreeze. Any other an ti freeze is
corrosive and can damage pump.

2.

Disconnect spark plug wire.

3. Connect length of garden hose

to water inlet of pump.

4.

Add RV antifreeze or windshield
washer fluid to hose as shown.

5. Pull engine starter rope slowly

several times until antifreeze/
washer fluid comes out of high-
pressure hose con nec tion of
pump.

6. Remove garden hose from water

inlet of pump.

7. Reconnect spark plug wire.

PRESSURE WASHER

1. Drain all water from high pressure

hose, coil it, and store it in cradle
of the pressure washer handle.

2. Drain all water from spray gun

and wand by holding spray gun
in a vertical position with nozzle
end pointing down and squeezing
trigger. Store in gun holder.

3. Store chemical hose so it is

protected from dam age.

4. If space is needed, remove

handles and replace as shown.

STORAGE

This manual is related to the following products: