Troubleshooting – Desa CRL2718 User Manual
Page 22
111160-01A
For more information, visit www.desatech.com
For more information, visit www.desatech.com
22
TROUBLESHOOTING
WARNING: Turn off and un-
plug heater and let cool before
servicing. Only a qualified ser-
vice person should service and
repair heater.
CAUTION: Never use a wire,
needle, or similar object to clean
ODS/pilot. This can damage ODS/
pilot unit.
POSSIBLE CAUSE
1.
Ignitor electrode not connected to
ignitor cable
2.
Ignitor cable pinched or wet
3.
Piezo ignitor nut is loose
4.
Broken ignitor cable
5.
Bad piezo ignitor
6.
Ignitor electrode broken
7.
Ignitor electrode positioned wrong
1.
Gas supply turned off or equipment
shutoff valve closed
2.
Control knob not in PILOT position
3.
Control knob not pressed in while in
PILOT position
4.
Air in gas lines when installed
5.
Depleted gas supply (propane/LP only)
6.
ODS/pilot is clogged
7.
Gas regulator setting is not correct
1.
Control knob not fully pressed in
2.
Control knob not pressed in long enough
3.
Equipment shutoff valve not fully open
4.
Pilot flame not touching thermocouple,
which allows thermocouple to cool,
causing pilot flame to go out. This
problem could be caused by one or both
of the following:
A) Low gas pressure
B) Dirty or partially clogged ODS/pilot
5.
Thermocouple connection loose at con-
trol valve
6.
Thermocouple damaged
7.
Control valve damaged
REMEDY
1.
Reconnect ignitor cable
2.
Free ignitor cable if pinched by any
metal or tubing. Keep ignitor cable dry
3.
Tighten nut holding piezo ignitor to
base panel of log set. Nut is located
behind base panel
4.
Replace ignitor cable
5.
Replace piezo ignitor
6.
Replace pilot assembly
7.
Replace pilot assembly
1.
Turn on gas supply or open equipment
shutoff valve
2.
Turn control knob to PILOT position
3.
Press in control knob while in PILOT
position
4.
Continue holding down control knob.
Repeat igniting operation until air is
removed
5.
Contact local propane/LP gas company
6.
Clean ODS/pilot (see Cleaning and
Maintenance, page 21) or replace ODS/
pilot assembly
7.
Replace gas regulator
1.
Press in control knob fully
2.
After ODS/pilot lights, keep control
knob pressed in 30 seconds
3.
Fully open equipment shutoff valve
4.
A) Contact local propane/LP or natu-
ral gas company
B) Clean ODS/pilot (see Cleaning and
Maintenance, page 21) or replace ODS/
pilot assembly
5.
Hand tighten until snug, then tighten
1/4 turn more
6.
Replace pilot assembly
7.
Replace control valve
OBSERVED PROBLEM
When ignitor button is pressed, there is no
spark at ODS/pilot
When ignitor button is pressed, there is
spark at ODS/pilot but no ignition
ODS/pilot lights but flame goes out when
control knob is released
Note:
For additional help, visit DESA’s
technical service web site at
www.desatech.com
.
Note:
All troubleshooting items are listed in
order of operation.
TROUBLESHOOTING