beautypg.com

Owner’s manual, Troubleshooting – Desa CGN20 User Manual

Page 13

background image

13

103568

OWNER’S MANUAL

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

Burner backfiring during
combustion

Yellow flame during burner combustion

Slight smoke or odor during initial opera-
tion

Heater produces a whistling noise when
burner is lit

POSSIBLE CAUSE

1. Burner orifice is clogged or damaged

2. Inlet gas pressure is too low
3. Burner damaged
4. Gas regulator defective

1. Not enough air

2. Inlet gas pressure is too low
3. Gas regulator defective

1. Residues from manufacturing processes

1. Turning control knob to HIGH position

when burner is cold

2. Air in gas line

3. Air passageways on heater blocked

4. Dirty or partially clogged burner orifice

REMEDY

1. Clean burner (see Cleaning and Mainte-

nance, page 11) or replace burner orifice

2. Contact local natural gas company
3. Replace burner
4. Replace gas regulator

1. Check burner for dirt and debris. If found,

clean burner (see Cleaning and Mainte-
nance
, page 11)

2. Contact local natural gas company
3. Replace gas regulator

1. Problem will stop after a few hours of

operation

1. Turn control knob to LOW position and

let warm up for a minute

2. Operate burner until air is removed from

line. Have gas line checked by local natu-
ral gas company

3. Observe minimum installation clearances

(see Figure 4, page 6)

4. Clean burner (see Cleaning and Mainte-

nance, page 11) or replace burner orifice

Continued