Starting – REMKO AMT 60E User Manual
Page 8

8
Important Hints!
◊
When the container is reinstalled make sure that it is
in the correct position.
◊
Make sure not to damage the micro switch.
◊
When the unit is in uncontrolled continuous opera-
tion, the condensate should be drained into a dis-
charge pipe or sink installed at a lower level.
Operation with hose connection (AMT 60-E)
The condensate trap is equipped with a hose nipple.
When the water container has been removed, a stan-
dard water hose (is not included in our delivery) can be
connected to the connecting branch.
Installation
of the water container (only AMT 60-E)
We recommend cleaning of the container with a clean
cloth after its removal.
floater
When the unit has been switched off the evaporator can
further defrost through the ambient temperature.
The unit stops working.
The yellow control lamp on the
switchboard lights up.
Remove the filled container.
For this purpose lift the con-
tainer slightly and then pull it
carefully forward to remove it.
You can empty the condensate
into a drain pipe or sink.
Make sure that condensate
does not continue dripping!
floater
strap
condensate trap
microswitch
drain hose
hose nipple
Make sure that the discharge hose is installed to
a lower level, in such a way as to ensure unhin-
dered drainage of condensate from the conden-
sate tank.
1. Introduce the main plug into a prop-
erly protected plug socket.
230V/1~ 50 Hz / fuse 16 A
2. Put main switch into position „I”.
Green control lamp “operation” is lit
up.
3. Please note: the unit is switched on
time-delayed and then goes into the
continuous operation mode.
Starting
The filter of the unit is to be controlled and cleaned thor-
oughly before every use. If the air suction grille is dirty,
please cleaned it up like shown in chapter ”Maintenance
and Service”.
Operation with water container (only AMT 60-E)
In the water container there is a floater which interrupts
the dehumidification operation by means of a micro-
switch when the container is full.
The cleaned container
is to be carefully rein-
stalled into the unit.
The strap of the floater
has to face the inside of
the unit.
Observe sticker.
Operation with hose connection (AMT 90-E)
The unit AMT 90-E is equipped with a firmly installed
discharge hose. There several versions of discharging
the generated condensate:
Version A
The condensate is collected in
an adequately dimensioned re-
ceiver which is to be procured
by the user.
Make sure to empty and to con-
trol the receiver regularly.
Version B
The condensate is drained via a
hose extension piece into an
outlet which has been installed
at a lower level.
This offers the possibility of con-
tinuous operation without con-
trol.
Version C
The condensate can be col-
lected first in a receiver as de-
scribed under Version A and
then be fed by means of a small
submerged pump either to an
outlet installed at a higher level
or to the outside.
If there is no outlet at a lower
lever and no discharge pipe.