Technical data, Wiring diagram, Troubleshooting – REMKO TX 3000 User Manual
Page 6
![background image](https://www.manualsdir.com/files/802321/content/doc006.png)
6
Technical Data
Wiring Diagram
4
L1
PE
6
5
4
3
N
2
1
6
5
1A
2A
3A
4B
5B
6B
11
14
31
34
A1
A2
HR
KL
TB
M
HW
S
TH
PE
N
L1
230/1~ 50Hz
NK
ϑ
Series
TX 3000
Nominal heat output
kW
3,0
Air output
m³/h
300
Electrical connection
V
230/1~, N,
PE
Frequency
Hz
50
Rated current max.
A
13,1
Power consumption max.
kW
3,05
Fuse protection (required)
A (inert)
16
Sound pressure level L
pA
1m
1)
dB (A)
46
Dimensions Length mm
400
Width
mm
200
Height
mm
340
Weight
kg
8,0
1) noise measuring DIN 45635 - 01 - KL 3
Legend
HR = contactor
HW = heating element
KL = terminal
strip
M = fanmotor
NK = recool thermostat
S = operating switch
TB = temperature
limiter
TH = room thermostat
Troubleshooting
Unit (fan) does not start:
1. Check main fuse
2. Check connecting cable with plug
3. Check operating switch
4. Check slight drifting of fan (motor)
Unit does not heat
1. Check operating switch
2. Check function of the temperature limiter
3. Check room thermostat
4. Check room thermostat-operation: thermostat must
be set higher than the room temperature
Should the unit still not be working despite these checks,
please contact an authorised service centre.
Prior to starting any work make sure to pull the
mains plug out of the mains socket!
Setting and maintenance is to be carried out
only by authorised experts!