Dynacord DPA 4120 User Manual
Page 44

44
13.
Extension kit specifications for the power amplifiers DPA 4120 / DPA 4140
13.1
NRS 90225 standard input module
see specifications DPA 4120 / DPA 4140
13.2
NRS 90222 remote module
see specifications DPA 4120 / DPA 4140
13.3
NRS 90208 input transformer for floating, balanced input
frequency response
20 Hz .. 20 kHz
input impedance
t 10 k ohms
idling ratio
1:1
winding resistance; primary
1420 ohms at 20°C
winding resistance; secondary
1420 ohms at 20°C
13.4
NRS 90227 output transformer for floating, balanced monitor output
frequency response
40 Hz .. 20 kHz
nominal load impedance
t 600 ohms
idling ration
1:1
winding resistance; primary
18 ohms at 20°C
winding resistance; secondary
18 ohms at 20°C
13.5
NRS 90224 pilot tone & ground fault surveillance
13.5.1 pilot tone surveillance
pilot tone frequency
19 kHz ± 1%
error recognition threshold
d 12 mV
fault message output via NRS 90225
collective fault message via READY relay
fault message output via NRS 90222
PROMATRIX manager DPM 4000
13.5.2 ground fault surveillance
input loudspeaker line 4 ohms / 50V / 70V / 100V
fault message output via NRS 90225
collective fault message via READY relay
fault message output via NRS 90222
PROMATRIX Manager DPM 4000
disruptive strength
1000 Veff
error recognition threshold
d 50 k ohms