Troubleshooting, Technical data, Wiring diagram – REMKO EST User Manual
Page 7: Service and guarantee

7
Troubleshooting
If your unit is not heating, follow these steps to find the
problem.
1. Check main fuse.
2. Check main plug.
3. Check connecting cable.
4. Make sure the heating resistor is working.
The heating resistor may only be replaced by an
authorised service centre.
Should the unit still not work after performing these
checks, please contact an authorised service centre.
Technical Data
Model EST
Nominal heat output kW 2
Electrical connection V 230/1~
Frequency Hz 50
Rated current A 9,1
Protection class I
Power consumption kW 2
Fuse protection A (inert) 16
Dimensions- Wall unit
Length mm 195
Width mm 770
Height mm 225
Weight kg 7,7
Dimensions- Standing unit
Length mm 305
Width mm 305
Height mm 905
Weight kg 10,0
Wiring Diagram
230V/1~ 50 Hz
L1 N PE
Heating element
Correct usage
The units are to be used only for heating and ventilation
purpose in industrial or commercial application because
of their construction and equipment.
If specification of the manufacturer or legal regulations,
are not followed or if unauthorised changes are made
on the unit, the manufacturer is not liable for resulting
damages.
An operation/use other than that indicated in these
instructions is prohibited!
In the case of non-observation we will not be held
responsible and our guarantee will become void.
Service and Guarantee
Any claims under guarantee regarding materials can be
accepted only when the orderer or his customer has
filled in completely the “guarantee certificate” which is
enclosed with every REMKO-heater and has returned it
to REMKO GmbH & Co. KG in due time after the unit’s
sale and commissioning.
The units are factory tested on faultless function. If any
failure occurs though which cannot be eliminated by the
operating person, please contact your dealer or contact
person.
Prior to starting any work make sure to pull the
mains plug out of the mains socket!
Maintenance work may only be performed by
authorised personnel.
Please conduct an electrical safety test after serv-