Commissioning – REMKO ELT 2-1 User Manual
Page 5

5
Operation
The units can be used in the
respective modes for air heating
and air circulation.
The units are operated on one heat
and one fan setting. They have a
three-position operating switch
with the functions:
Heat (I)/Off (0)/Fan (II).
In the setting I (Heat), the heating
resistor and air circulating fan are
switched on and warm air is blown
out.
In order to ensure a constant
room temperature, the unit has an
integrated room thermostat.
The thermostat switches off
the heater when the selected
temperature is reached and
switches it on again when the
temperature falls below the
selected value.
The integrated temperature
limiter switches off the unit if the
temperature is excessively high and
switches it on again automatically
after it has cooled down.
In the setting II (Fan), only the air
circulating fan is switched on and
the unit can only be used for air
circulation.
After switching off the unit at
the operating switch or room
thermostat, the air supply fan
continues to run for a certain
period of time to cool the
heating resistors and switches off
automatically.
Commissioning
Heat
The unit operates fully
automatically depending on the
temperature set at the thermostat.
1. Setting the required
room temperature
at the thermostat
2. Set the operating switch
to position “I” Heat.
Fan
In this position, only the supply air
fan runs. Thermostatic control and
heating are not possible.
1. Set the operating switch
to position “II” Fan.
Operation and monitoring of the
units must be carried out by one
person who has been adequately
instructed in the use of the unit.
1. Check the system voltage for
correspondence with the unit
voltage 230V/1~/50 Hz.
2. Set the operating
switch to position
“0“.
3. Plug the unit into
a properly installed
mains socket-outlet.
NOTE
Electrical connection of the
units must be made at a
separate supply point using
a residual-current-operated
circuit-breaker according to
VDE 0100 § 55.
NOTE
For optimal operation, the
units should not be operated
at ambient temperatures above
25°C.
ATTENTION
Only authorised electricians
may extend the connecting
cable taking into account the
rating of the unit, cable length
and use locally.
ATTENTION
All cable extensions must
be used only uncoiled or
unwound.