beautypg.com

Operation, Concerto toilet operation – Dometic 3210 User Manual

Page 6

background image

6

STEP 17: Connect the positive (+) 12 VDC lead to the red
wire and the negative (-) lead to the black wire (fig. 18).

Fig. 18

STEP 18: REMOVE RED CAP FROM MIDDLE
OF FLANGE ADAPTER BEFORE FINAL TOILET
INSTALLATION.

IMPORTANT – DO NOT ATTEMPT TO SLIDE THE
TOILET OVER THE FLANGE ADAPTER. THE
TOILET MUST BE SET DOWN OVER THE ADAPTER
TO PREVENT POSSIBLE DAMAGE.

STEP 19: Set the toilet in place (fig. 19) and secure to floor
with the #14x2-1/2 inch long lag bolts (fig. 20). Install deco-
rative bolt caps by pushing them onto bolt heads (fig. 21).
STEP 20: Place the rear access cover on the back of the
toilet. Press down firmly to seat the fastening strips.

Fig. 21

Fig. 19

Fig. 20

STEP 21: Turn on electrical power and water to toilet. Lift
flush handle and fill toilet bowl with water. Wait one hour,
then inspect the floor around and under the rear of the
toilet for leaks or dampness.

CONCERTO TOILET OPERATION

1. Fill freshwater tank and add deodorant to holding tank through toilet bowl.
2. Make sure all guests understand the operation of the toilet system and

the flushing instruction label is easy for guests to read. This label is
located under the seat, and is easily read when the seat is raised.

3. Shut off the toilet system before servicing and do not leave the vehicle with

toilet system breaker on.

4. Never use drain openers, alcohol, solvents, etc. in the toilet.
5. If the toilet does not function properly, refer to the Troubleshooting

section of this manual and repair as necessary. If problem persists, contact your local SeaLand product dealer or
see the Customer Service section of this manual.

1. To add water to the toilet before

using (if necessary), raise flush

handle until desired water level is

reached.

2. To flush toilet, press flush handle

down. Release handle to let flush

ball snap back into position.

3. Do not dispose of sanitary

napkins or other non-dissolving

items in toilet, such as facial

tissue or paper towels. These items

can plug the system.

FLUSHING OPERATION