Limiting functions, Operating reserve, Return to factory configuration – Radson Confort Pilot User Manual
Page 2: Specific recommendations, Maintenance
2
press the [+] or [-] button to adjust the tempera-
ture shown to match the room temperature.
• To set the new values, press briefly on the
button.
• Example: the display shows 20° C and the
thermometer shows 22° C. Press the [+] button
until the display shows 22° C.
Note: if only the ‘frost outside’ indicator light [*]
is flashing, it means that the room temperature is
outside [i.e. higher or lower than] the calibrated zone
[18°C recalibrate the thermostat. LIMITING FUNCTIONS The following 2 functions may be useful in the case of appliances installed in premises accessible to the public. Limiting thermostat If you want to restrict the ambient temperature to a predefined level: • Press the button for at least 5 seconds. The indicator light corresponding to the maximum value allowed starts flashing. This value can be increased by pressing the [+] or [-] button. • To validate the new value, briefly press the button. Deactiving the timer If you want to lock the forced operation by 2hr timer: • Press the button and [-] simultaneously for at least 5 seconds. - The 2 hr indicator light starts flashing for 5 seconds to indicate it has taken the command into account. • To validate the new value, briefly press the button. OPERATING RESERVE Even if there is a power cut, the appliance keeps the setting from before the cut in its memory, excepting the function “Confort Pilot”. RETURN TO FACTORY CONFIGURATION • Simultaneously press the [+] and [-] buttons for 10 seconds to return to the initial configuration: - Adjustment mode setting Frost free or pilot wire. - No correction of measured temperature. - Setting restriction, positioned on max tempera- ture [26°C]. - Timer function unlocked. - Removal of timer daily repetition. SPECIFIC RECOMMENDATIONS Mixed appliances The mixed appliances are provided to operate with 2 different types of power: central heating/electric heating. These 2 power types must never operate simultaneously. • When operating on central heating, the electric part must be closed. • If you want to operate the electric part, it is advisable to close the tap mounted on the hot water supply, but in this case, never totally isolate the radiator [never shut the return of the cen- tral heating circuit, in order to leave free passage for dilation towards the expansion tank of the installation]. • Never operate the electric part without having checked that the radiator is full of water by purg- ing the air out and adding water if necessary. The purge must be carried out, either with pump stopped, or supply tap closed. Switching on without the appliance being properly filled with water will result in the cancellation of the guarantee. Electric radiators During use, you will be able to note that the top and bottom elements are not as warm as the rest of the radiator: • The top elements are not completely filled to allow dilation of the heat transfer fluid when heating. • The bottom elements receive the return fluid which has transmitted its heat. SPECIFIC CASE OF ADJUSTMENT BY PILOT WIRE [BLACK WIRE] The electronic thermostat allows the orders sent by EDF [cf. Tariff Tempo] to be managed. It also allows them to be viewed: Orders generated by your programmer 1. Comfort: normal mode, the temperature set point indicator light is on. 2. Reduced: temperature set point flashes. 3. Frost free: the 1st indicator light is on solidly. 4. Off: the heat indicator light [C] is on solid. Orders generated by EDF 5. Comfort -1°C: the set point indicator light flashes with single impulse. 6. Comfort -2°C: the set point indicator light flashes with double impulse. MAINTENANCE Do not use chemically aggressive or abrasive products. A cloth moistened with alcohol will be suitable after having let the appliance cool down. Preferably use a dry soft cloth for cleaning the casing.