beautypg.com

1 2 fp m – Paso Sound 7539 User Manual

Page 2

background image

Description

Speakerphone monitor with 3.5” colour LCD screen for Due Fili Plus systems. It has a capacitive keypad with buttons for answering calls, unlocking,
self-starting, auxiliary services, adjustments to volume, brightness and contrast.
It is possible to differentiate the call chimes. The visual signals are for
“door/gate open,” “missed calls,” “user away” and “chime muting.”

Article 7539 features a hearing aid function.

Technical characteristics

Surface-wall mount or box installation (can be fitted to the wall with plugs or a rectangular type 503 or circular 60 or 70 mm flush-mounting box).
‡ ´/&'GLVSOD\
‡ &DSDFLWLYHWRXFKNH\SDGZLWKEDFNOLWV\PEROV
‡ 3RZHUVXSSO\IRUWHUPLQDOV9GF
‡ $EVRUSWLRQ
RQVWDQGE\P$
PD[LPXPFRQYHUVDWLRQFXUUHQWP$
SHDNFXUUHQWOLPLWHGWRFDOOWLPHP$
‡$PELHQWFODVV&ODVV$LQGRRUXVH
‡ 2SHUDWLQJWHPSHUDWXUHƒWRƒ&
‡ 2SHUDWLQJDPELHQWKXPLGLW\QRQFRQGHQVLQJ
‡ (OHFWURQLFFKLPHVZLWKGLIIHUHQWWXQHV
‡ ,QSXWIRUODQGLQJFDOO
‡ 'LPHQVLRQV[[PP
‡ ',3VZLWFKIRUOLQHLPSHGDQFHWHUPLQDWLRQ

2

CONTENTS

Description.....................................................................................................................................................................................................................................................................

Technical characteristics................................................................................................................................................................................................................................................

Installation .....................................................................................................................................................................................................................................................................

Functions of the buttons ...............................................................................................................................................................................................................................................

Preliminary procedures..................................................................................................................................................................................................................................................

Manual ID configuration.................................................................................................................................................................................................................................................

Master ID and secondary ID correspondence table ......................................................................................................................................................................................................5

Configuring configurable buttons ...................................................................................................................................................................................................................................6

Configuring chimes ........................................................................................................................................................................................................................................................6

2SHUDWLRQ .......................................................................................................................................................................................................................................................................7

Impaired hearing operation ...........................................................................................................................................................................................................................................

SaveProg software ........................................................................................................................................................................................................................................................9

Wiring diagrams and variants ......................................................................................................................................................................................................................................

Warnings for the installer and standards .....................................................................................................................................................................................................................

1,60 / 1,65m

1,20 m

Fig. 1

Connection terminal block:

1, 2 = Bus terminals
FP = Input for landing call button (referring to terminal M).
M

=

(DUWKUHIHUHQFH

Installation

Secure the plate to the wall with plugs or on a box type 503 or a circular mounting box size 60mm
)LJDQG

:LUHWKHWHUPLQDOEORFNZKLFKLVLQWHJUDOZLWKWKHPRXQWLQJSODWH)LJDQG

3.

Terminate the video signal (Fig. 6)

Install the indoor station on the plate (Fig. 7)

5.

housed in the mounting plate (see Fig. 5).

Note

)LJVKRZVWKHUHFRPPHQGHGLQVWDOODWLRQGLVWDQFHVXQOHVVRWKHUZLVHVSHFLILHGE\FXUUHQWUHJXODWLRQV

1 2

FP

M

Fig. 2