Plus, Reference manual - utilities configuration, Rf 007 – Paso Sound DMS120P User Manual
Page 10: Utilities wiring diagram example, On off, Vox relay diagrams, Digital multi series, Vox relay trigger chime select trigger, Media, Ambient level controller electret microphone

plus
DIGITAL MULTI SERIES
MEDIA
REFERENCE MANUAL - UTILITIES CONFIGURATION
RF 007
COM
NC
NO
RL201
VOX RELAY
Q237
D211
+
VOX NOT ACTIVATED
A
COM
NC
NO
RL201
VOX RELAY
Q237
D211
+
VOX ACTIVATED
B
VOX RELAY DIAGRAMS
RVC10W MASTER
REMOTE
VOLUME CONTROL
10 K POT
UTILITIES WIRING DIAGRAM EXAMPLE
SHIELD
ELECTRET
HOT
COMMON
AMBIENT LEVEL CONTROLLER
ELECTRET MICROPHONE
MASTER
REMOTE VOL
UME
WIRING THE VOX RELAY
WHEN USING PRIORITY
ATTENUATORS. BOTH
POWER AND CONTROL
ARE PROVIDED.
ON
OFF
VOX
RELAY
TRIGGER
CHIME
SELECT
TRIGGER
AMBIENT LEVEL CONTROLLER
DEFEAT REMOTE SWITCH
MIX BUSS
ON - OFF SWITCH
CHIME/ALARM
ON - OFF SWITCH
DIRECT MUTE 1
ON - OFF SWITCH
DIRECT MUTE 2
ON - OFF SWITCH
REMOTE
ON - OFF
POWER SWITCH
PRIORITY ATTENUATOR
Atten
uator
Rela
y
COMMON
70 VOLT IN
24 V DC
OFF
ON
IN
OUT
70 V
olt
T
ransf
ormer
70 V
olt
T
ransf
ormer
70 VOLT SPEAKER
70 VOLT SPEAKER
Bridge
+ to C
THE VOX RELAY TRIGGER
SELECTOR IS SET ON M1.
WHEN THE VOX V1 IS ACTIVATED
THE VOX RELAY WILL SWITCH
ON.
THE CHIME TRIGGER
SELECTOR IS SET ON M2.
IF EQUIPPED WITH THE
OPTIONAL CHIME CARD
THE CHIME WILL SOUND
WHEN M2 IS SHORTED TO
GROUND
F
S
N
O
I
T
C
A
SLOW FAST
U
A
C
T
I
O
N
A
G
N
I
GATED OUTPUTS
PWR
GAIN REDUCTION
GAIN EXPANSION
OUTPUT
LINE LEVEL
OUTPUT
MIC LEVEL
INPUT
LINE LEVEL
GAIN CONTROL AMPLIFIER
THE 24 VOLT REGULATED
UTILITY POWER SUPPLY
CAN POWER EXTERNAL
MODULES AND OTHER
ACCESSORIES