beautypg.com

Technical specifications – OWON B35(T) User Manual

Page 29

background image

7.Technical Specifications

24

7. Technical Specifications

All these specifications apply to the multimeter unless otherwise explanation.
Note: "T" in the model indicates true RMS (optional).
Standard conditions: The environment temperature is 18℃ to 28℃, the relative

humidity is less than 80%.

Function

Measurement Range

Resolu-
tion

Accuracy

DC

Voltage

(V)

mV

60.00mV/600.0mV

0.01 mV

±(0.

5%+2dig)

V

60.00mV/600.0mV/6.000V/60.00V

0.1 mV

600.0V/1000V

0.1 V

AC

Voltage

(V)

mV

60.00mV/600.0mV

0.01 mV ±(0.8%+2dig)

V

60.00mV/600.0mV/6.000V/60.00V

1 mV

±(0.8%+2dig)

600.0V/750V

0.1 V

±(1%+3dig)

DC

Current

(A)

μA 600.0μA

0.1

μA

±(0.8%+2dig)

mA

600.0μA/6.000mA/60.00mA/
600.0mA/6.000A

0.01 mA ±(0.8%+2dig)

A

20.00A

[1]

1 mA

±(1.2%+3dig)

AC

Current

(A)

μA 600.0μA

0.1

μA

±(1%+3dig)

mA

600.0μA/6.000mA/60.00mA/
600.0mA/6.000A

0.01 mA ±(0.8%+2dig)

A

20.00A

[1]

1 mA

±(2%+3dig)

Resistance

(Ω)

600.0Ω/6.000kΩ/60.00kΩ/600.0kΩ/

6.000MΩ/10.00MΩ

0.1

Ω

±(0.8%+2dig)

60.00MΩ

0.01 MΩ ±(2%+3dig)

Capacitance

(F)

40.00nF

0.01 nF

±(2.5%+3dig)

400.0nF/4.000μF/40.00μF

0.1 nF

±(2.5%+3dig)

400.0μF/4000μF

[2]

0.1

μF

±(3%+5dig)

Frequency

[3]

(Hz)

9.999Hz/99.99Hz/999.9Hz/9.999k
Hz/99.99kHz/999.9kHz/9.999MHz

1 mHz

±(0.8%+2dig)

Duty Cycle

[4]

(%)

0.1% - 99.9%
(Typical: Vrms=1 V, f=1 kHz)

0.1%

±(1.2%+3dig)

0.1% - 99.9%(≥1 kHz)

±(2.5%+3dig)

Temperature

(°C/°F)

-50 ℃ to 400 ℃

1 ℃

±(2.5%+3dig)

-58 ℉ to 752 ℉

1 ℉

±(4.5%+5dig)

[1]

When

measuring current, for 10 A to 15 A, the measuring duration should not be over

2 minutes within 10 minutes, and in this 10 minutes, no other current should flow

through except within the measuring duration; for 15 A to 20 A, the measuring

duration should not be over 10 seconds within 15 minutes, and in this 15 minutes, no

other current should flow through except within the measuring duration.

[2]

When

measuring capacitance, for the 4000 uF range, the measuring duration should

This manual is related to the following products: